Waterworld new millenium Installation & Service Manual Download Page 9

7

MOUNTING THE FAUCET

Air Gap Faucet (Optional)

1)  Drill a 7/8” hole in the sink or the counter top, or use an 

existing hole.

2)  Slide chrome cover plate and rubber gasket on to 

stem of faucet and place faucet onto sink, with the 

stem going through the hole. 

3)  Place metal slotted washer over threaded 

stem of faucet.

4)  Place plastic spacer over 

threaded stem of faucet 

locking in place, slotted 

washer onto countertop. 

5)  Tighten nut from under 

the counter surface to lock the 

faucet into place. 

6)  Attach red ¼’’ drain water discharge line to DRAIN 

INPUT barb. And red 3/8’’ drain line to DRAIN 

OUTPUT barb as shown.

7)  Thread the faucet connector onto threaded stem of faucet. Do not use Teflon tape.

8)  Connect blue 3/8” tubing to faucet connector. 

Rubber gasket 

Drain line to air gap
1/4” red tubing

Drain line from air gap
to drain clamp 3/8” red tubing 

Darin Output

Darin Input

 

Chrome cover plate 

Plastic spacer 

Faucet connector 
3/8” X 7/16” 

Faucet nut 

Metal washer 

Slotted washer 

Sink or counter top material 

Blue 3/8” tubing 

(Fig. 4 B)

MOUNTING THE FAUCET

Standard Faucet

1)  Drill a ½” hole in the sink or the counter top, or use an 

existing hole.

2)  Slide chrome cover plate and rubber gasket 

on to stem of faucet and place faucet onto 

sink, with the stem going through the 

hole. 

3)  Place metal slotted 

washer over threaded 

stem of faucet.

4)  Tighten nut from under the counter surface to 

lock the faucet into place. 

5)  Thread the faucet connector onto threaded 

stem of faucet. Do not use Teflon tape.

6)  Connect blue 3/8” tubing to faucet connector. 

Rubber gasket

Chrome cover plate

Faucet connector
3/8” X 7/16”

Faucet nut

Metal toothed washer

Big metal washer

Sink or counter top material

Blue 3/8” tubing

(Fig. 4 A)

Summary of Contents for new millenium

Page 1: ...Installation Service Manual Reverse Osmosis Drinking Water Systems 75 GPD with Fully Automatic Noiseless Booster Pump...

Page 2: ...Distributed by Serial...

Page 3: ...ECTRICAL EQUIPMENT IF UNCERTAIN CONSULT AN ELECTRICIAN ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL AND STATE ELECTRICAL CODES Before installing you will need to make sur...

Page 4: ...line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball valve on...

Page 5: ...er supply line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball...

Page 6: ...t is used DC 38J Drain Clamp used for tapping into drainline for discharge of the wastewater down the drain when air gap faucet is used Teflon Tape 5 Teflon Tape Teflon Tape is used on all threaded fi...

Page 7: ...the 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 PPASV121208W Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the PPASV...

Page 8: ...en starting the hole Use a special porcelain hole cutter 4 For Stainless Steel Sink Before using the selected bit an indent should be made with a center punch to keep the drill bit from moving A small...

Page 9: ...ket Drain line to air gap 1 4 red tubing Drain line from air gap to drain clamp 3 8 red tubing Darin Output Darin Input Chrome cover plate Plastic spacer Faucet connector 3 8 X 7 16 Faucet nut Metal w...

Page 10: ...ig 7 5 Connect the 1 4 red tubing to the drain clamp or 3 8 when air gap faucet is used Sink Mount drain saddle at either location Never mount here DRAIN CLAMP INSTALLATION 1 The drain clamp assembly...

Page 11: ...AP FAUCETS Connector White Plastic Sleeve Compression nut Plastic Tubing Brass Insert Fig 8 Fig 9 To disconnect ensure the system is depressurized before removing the tube Push in collet squarely agai...

Page 12: ...HE FIRST TANK PRODUCED BY THE SYSTEM COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET DISCHARGING MIGHT TAKE UP TO 15 MIN If you have any difficulties with the installation or require a...

Page 13: ...hould you require additional information or need further technical assistance on Millennium system contact your local dealer 5 Drain your storage tank frequently to ensure the freshness of the water i...

Page 14: ...1 8 to turn with housing wrench DO NOT OVER TIGHTEN Over tightening will cause cracks and leaks if not careful CAUTION ALWAYS MAKE SURE THAT O RINGS ARE SEATED PROPERLY INSIDE SUMPS BEFORE TIGHTENING...

Page 15: ...F WATER 2 BLADDER IN TANK IS RUPTURED TANK MUST BE REPLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP I...

Page 16: ...o event shall Factory its subsidiaries or affiliates or their respective officers directors employees representatives dealers or agents be liable for special incidental consequential punitive indirect...

Reviews: