CHANGING THE FILTERS

CAUTION: ANY REPLACEMENT FILTERS OR MEMBRANES NOT RECOMMENDED BY THE 

FACTORY CAN CAUSE SEVERE DAMAGE TO THE SYSTEM AND VOID ALL WARRANTIES.

MAINTENANCE

Before starting maintenance, check the reverse osmosis system for TDS reduction to determine 

if membranes will or will not need to be changed.

If TDS reduction is less than 90% concentration, then the membrane should be replaced. 

1)  Shut off the water supply to the system.
2)  Close storage tank ball valve.

3)  Open the dispensing faucet to depressurize the system. (Allow 2 to 3 minutes).
4)  Remove the filter housings by turning counter-clockwise.
5)  Remove old filters and clean housings with a mild soap and water solution.

6)  Check o-rings for deterioration and lubricate with an approved FDA silicone lubricant for 

o-rings or replace if needed.

7)  Insert the appropriate new filters inside housings and replace them by mounting them 

in to position.  Make hand tight plus 1/8 to ¼ turn with housing wrench. DO NOT OVER-

TIGHTEN.  Over-tightening will cause cracks and leaks if not careful.

CAUTION: ALWAYS MAKE SURE THAT “O”-RINGS ARE SEATED PROPERLY INSIDE 

SUMPS BEFORE TIGHTENING CANISTERS.

8)  If a membrane needs changing, remove the inlet tubing to the housing, unscrew the cap, 

and pull the membrane out using a needle nosed pliers.  Clean the inside of the membrane 

housing with a mild soap and water solution.

9)  Lubricate the o-rings on the membrane permeate tube with an approved FDA silicone lu

-

bricant. Insert into the housing with brine seal towards the opening. Make sure membrane 

is fully inserted and seated into place. 

10)  Reseal the membrane housing with the cap and reconnect tubing.

11)  To replace the carbon in-line post filter, remove the tubing and fittings at either end.  Clean 

the old Teflon tape off the threads and apply new tape.  Screw the fittings into the new 

cartridge paying close attention to the flow direction. Reinsert tubing.

REPLACEMENT FILTERS:

1) First Stage: 

item# CP110

2) Second Stage:

item# UDF-10

3) Third Stage:

item# 32-250-125-975

4) Fourth Stage:

item# TW30-1812-75

5) Fifth Stage:

item# K2540-BB

Summary of Contents for new millenium

Page 1: ...Installation Service Manual Reverse Osmosis Drinking Water Systems 75 GPD with Fully Automatic Noiseless Booster Pump...

Page 2: ...Distributed by Serial...

Page 3: ...ECTRICAL EQUIPMENT IF UNCERTAIN CONSULT AN ELECTRICIAN ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL AND STATE ELECTRICAL CODES Before installing you will need to make sur...

Page 4: ...line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball valve on...

Page 5: ...er supply line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball...

Page 6: ...t is used DC 38J Drain Clamp used for tapping into drainline for discharge of the wastewater down the drain when air gap faucet is used Teflon Tape 5 Teflon Tape Teflon Tape is used on all threaded fi...

Page 7: ...the 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 PPASV121208W Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the PPASV...

Page 8: ...en starting the hole Use a special porcelain hole cutter 4 For Stainless Steel Sink Before using the selected bit an indent should be made with a center punch to keep the drill bit from moving A small...

Page 9: ...ket Drain line to air gap 1 4 red tubing Drain line from air gap to drain clamp 3 8 red tubing Darin Output Darin Input Chrome cover plate Plastic spacer Faucet connector 3 8 X 7 16 Faucet nut Metal w...

Page 10: ...ig 7 5 Connect the 1 4 red tubing to the drain clamp or 3 8 when air gap faucet is used Sink Mount drain saddle at either location Never mount here DRAIN CLAMP INSTALLATION 1 The drain clamp assembly...

Page 11: ...AP FAUCETS Connector White Plastic Sleeve Compression nut Plastic Tubing Brass Insert Fig 8 Fig 9 To disconnect ensure the system is depressurized before removing the tube Push in collet squarely agai...

Page 12: ...HE FIRST TANK PRODUCED BY THE SYSTEM COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET DISCHARGING MIGHT TAKE UP TO 15 MIN If you have any difficulties with the installation or require a...

Page 13: ...hould you require additional information or need further technical assistance on Millennium system contact your local dealer 5 Drain your storage tank frequently to ensure the freshness of the water i...

Page 14: ...1 8 to turn with housing wrench DO NOT OVER TIGHTEN Over tightening will cause cracks and leaks if not careful CAUTION ALWAYS MAKE SURE THAT O RINGS ARE SEATED PROPERLY INSIDE SUMPS BEFORE TIGHTENING...

Page 15: ...F WATER 2 BLADDER IN TANK IS RUPTURED TANK MUST BE REPLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP I...

Page 16: ...o event shall Factory its subsidiaries or affiliates or their respective officers directors employees representatives dealers or agents be liable for special incidental consequential punitive indirect...

Reviews: