Waterworld new millenium Installation & Service Manual Download Page 3

1

Please read this entire service guide prior to beginning installation.  

REVERSE OSMOSIS SYSTEM WITH BUILT IN PUMP

Congratulations on choosing the Millennium Reverse Osmosis System.  Our high quality reverse 

osmosis system has been designed and tested to give you trouble free performance for many years 

with proper maintenance.  Please carefully read through this manual before installing the system.  

Make yourself familiar with all the parts, components, and installation procedures before continuing.

The Millennium unit is equipped with a pressure booster pump for the membrane.  This is required 

where feed pressure is below 40 PSI, but higher than 5 PSI. It is also useful when higher production 

rates are required.  This system is also equipped with a high and low pressure switch to operate and 

protect the pump.

CAUTION: ALWAYS CONSIDER ELECTRICAL SHOCK HAZARD WHEN WORKING WITH AND 

HANDLING ELECTRICAL EQUIPMENT. IF UNCERTAIN, CONSULT AN ELECTRICIAN. ELECTRICAL 

WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL AND STATE  

ELECTRICAL CODES.

Before installing you will need to make sure that you have a dedicated power supply under the 

sink, or within 4 feet of the system.  We highly recommend a GFI outlet to plug the unit into as this 

system is usually located near numerous water supplies.  Follow all electrical and plumbing codes 

and be certain of the voltage requirements on the Millennium unit. For installation assistance, contact 

your local dealer. 

We have supplied the system with Color coded tubing for ease of installation.

The following tools will be required for your installation:v

1)  Hand drill for faucet hole.  Use the appropriate bit for the surface you are drilling. (½” for non 

air gap faucets and - 7/8” drill bit for air gap ones).

 

A)  Titanium bit for metal sinks.

 

B)  Glass and tile bit or Relton cutter for porcelain sinks.

 

C)  Diamond core bit for granite.

2)  Phillips head screwdriver.
3)  Adjustable crescent wrench.
4)  Basin wrench.
5)  ¼” drill bit for drain clamp.

Your local dealer

Summary of Contents for new millenium

Page 1: ...Installation Service Manual Reverse Osmosis Drinking Water Systems 75 GPD with Fully Automatic Noiseless Booster Pump...

Page 2: ...Distributed by Serial...

Page 3: ...ECTRICAL EQUIPMENT IF UNCERTAIN CONSULT AN ELECTRICIAN ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL AND STATE ELECTRICAL CODES Before installing you will need to make sur...

Page 4: ...line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball valve on...

Page 5: ...er supply line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball...

Page 6: ...t is used DC 38J Drain Clamp used for tapping into drainline for discharge of the wastewater down the drain when air gap faucet is used Teflon Tape 5 Teflon Tape Teflon Tape is used on all threaded fi...

Page 7: ...the 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 PPASV121208W Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the PPASV...

Page 8: ...en starting the hole Use a special porcelain hole cutter 4 For Stainless Steel Sink Before using the selected bit an indent should be made with a center punch to keep the drill bit from moving A small...

Page 9: ...ket Drain line to air gap 1 4 red tubing Drain line from air gap to drain clamp 3 8 red tubing Darin Output Darin Input Chrome cover plate Plastic spacer Faucet connector 3 8 X 7 16 Faucet nut Metal w...

Page 10: ...ig 7 5 Connect the 1 4 red tubing to the drain clamp or 3 8 when air gap faucet is used Sink Mount drain saddle at either location Never mount here DRAIN CLAMP INSTALLATION 1 The drain clamp assembly...

Page 11: ...AP FAUCETS Connector White Plastic Sleeve Compression nut Plastic Tubing Brass Insert Fig 8 Fig 9 To disconnect ensure the system is depressurized before removing the tube Push in collet squarely agai...

Page 12: ...HE FIRST TANK PRODUCED BY THE SYSTEM COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET DISCHARGING MIGHT TAKE UP TO 15 MIN If you have any difficulties with the installation or require a...

Page 13: ...hould you require additional information or need further technical assistance on Millennium system contact your local dealer 5 Drain your storage tank frequently to ensure the freshness of the water i...

Page 14: ...1 8 to turn with housing wrench DO NOT OVER TIGHTEN Over tightening will cause cracks and leaks if not careful CAUTION ALWAYS MAKE SURE THAT O RINGS ARE SEATED PROPERLY INSIDE SUMPS BEFORE TIGHTENING...

Page 15: ...F WATER 2 BLADDER IN TANK IS RUPTURED TANK MUST BE REPLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP I...

Page 16: ...o event shall Factory its subsidiaries or affiliates or their respective officers directors employees representatives dealers or agents be liable for special incidental consequential punitive indirect...