![Waterworld new millenium Installation & Service Manual Download Page 10](http://html1.mh-extra.com/html/waterworld/new-millenium/new-millenium_installation-and-service-manual_3685898010.webp)
8
3) Affix sponge provided with the drain clamp onto inside of clamp
piece matching the holes. The center hole on the sponge must
be removed.
4) Make sure to align drain saddle to drilled hole. Attach drain
clamp to drain pipe and tighten the two screws evenly (Fig. 7)
5) Connect the 1/4” red tubing to the drain clamp (or 3/8” when air
gap faucet is used).
Sink
Mount drain
saddle
at either location
Never mount here
DRAIN CLAMP INSTALLATION
1) The drain clamp assembly should be installed
above the trap and on the vertical or horizontal
tail piece (Fig. 5)
2) Mark the hole position on the pipe and drill a ¼’’ hole through
one side of the pipe. (Fig. 6). Be careful
not
to drill the hole
through both sides of the pipe.
(Fig. 5)
(Fig. 6)
(Fig. 7)