![Waterworld new millenium Installation & Service Manual Download Page 13](http://html1.mh-extra.com/html/waterworld/new-millenium/new-millenium_installation-and-service-manual_3685898013.webp)
11
(Fig.10)
CAUTION:
Do not use the Millennium System on feedwater pressure above 40 psi.
If feedwater pressure is above 40 psi, contact your local dealer for an alternative
system not equipped with a booster pump.
IMPORTANT NOTES-MUST READ:
1) Your Millennium
®
system has been thoroughly tested and inspected for
production, leaks, and shut-off functions at our factory. Therefore, it might
have some water in it.
2) Do not use this system on feed water that has biological contamination or
if feed water is of unknown source.
3) All local plumbing codes must be followed to ensure proper installation
and use of your Millennium
®
RO System.
4) Flush your RO system (using manual flushing valve located on the unit
assembly) frequently. Flushing the system for 5 minutes at a time will
enhance the quality and prolong the life of the TFC membrane.
5) Should you require additional information or need further technical
assistance on Millennium
®
system, contact your local dealer.
5) Drain your storage tank frequently to ensure the freshness of the water in the
storage tank by lifting the faucet handle into the open position until water flow stops
from the tank. Return the faucet handle to the closed position and the tank will refill
in 2 hours. It is best to drain the system before retiring for the evening
6) Manual Flushing: Flushing your system routinely (for 5 minutes each time) will
enhance the performance and prolong the life of the TFC membrane.
HOW TO MANUALLY FLUSH THE MEMBRANE
The Manual Flushing Device is located in between the Membrane Housing and the Post
Carbon on top of the Millennium RO unit.
Flushing Instructions:
1) Close tank valve
2) Open faucet handle
3) Rotate flushing ball valve to FLUSH position for 5 minutes
4) Open tank ball valve and close faucet handle (normal
settings)
5) Return flush ball valve to IN SERVICE position (closed)
In service
(closed)
Flush
(Open)
Summary of Contents for new millenium