Pre‐installation and sanitization procedures as prescribed in this manual must be performed before
installing the
WL500 Water Treatment System
.
Always install indoors and place the
Waterlogic WL500
Water Treatment System
on a firm, flat and
stable surface.
Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.
Waterlogic
requires the use of a water pressure regulator. Water feed pressure must be between 40‐
60 psi. Turn on the water supply and check for leaks.
1.
Check to ensure that both the RED Power Switch and the GREEN Heater /
Compressor switches are in the
O=OFF
position.
NOTE:
Switches have internal
LED that illuminates when placed in
I=ON
position.
2.
Connect the power cord to the back of the
Waterlogic WL500
Water
Treatment System
and to a 120 Volt supply.
3.
Turn the RED Power Switch to I=ON position.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
GREEN Compressor/Heater Switch must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the overload (high
limit) will require manual reset if heater is turned on with an empty Hot Tank.
4.
Prime the Cold Circuit. Holding a container under the dispensing faucet, press and hold the main
dispensing button until a continuous flow of water is obtained. Once a continuous flow is obtained,
release the dispensing button. Cold Tanks are now full.
5.
Prime the Hot Tank. Holding a container under the dispensing faucet, press the hot button (Button
3) followed by the main dispensing button until a continuous flow of water is obtained. Once a
continuous flow is obtained, release the main dispensing button. Hot Tank is now full.
6.
Prime the Sparkling Circuit. Holding a container under the dispensing faucet, press the sparkling
button (Button 2) followed by the main dispensing button until all water is dispensed and a
continuous flow of gas is obtained. Once a continuous flow of gas is obtained, release the main
dispensing button and the Sparkling Tank will regenerate itself.
7.
Verify that the UV Lamp operates as expected (no alarm annunciated on the display).
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Always disconnect before removal.
8.
Press the cold button and dispense cold‐water into the drip tray to test the alarm. Ensure that the
drip tray alarm will sounds for 15 seconds, Drip Tray Fault is present on the LCD display, and the unit
cuts off water supply. Empty the drip tray and wipe dry. While the drip tray is unattached from the
front Panel dry the alarm sensor connectors. Carefully install drip tray to avoid damage to the metal
sensor clips. Do not jam drip tray back into the unit and make sure it is properly seated.