INSTALLATION PROCEDURES
Safety and Installation Guidelines
Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met when
installing
Waterlogic
Equipment. Only qualified service technicians should attempt installation and
service of
Waterlogic
Equipment.
WARNING!
ELECTRICAL SHOCK HAZARD.
Always unplug (isolate from power supply) to prevent
electrical shock except where electrical tests are specified.
WARNING!
IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK.
Connect to a 15 amp 120V 60Hz properly grounded outlet (GFI is recommended). Ensure polarity is
correct and always use a 3‐prong outlet. Consult a qualified electrician if you have any questions.
WARNING!
USE ONLY Waterlogic SUPPLIED POWER CORD (WLCP PN 10‐3007).
Locate system
within 5 feet of power supply. Never use an extension cord or adapter. Do not use a damaged
power cord or plug. Keep power cord out of heavy traffic areas and away from heat sources. Do
not, under any circumstances, remove ground prong or alter the power cord. Never pull the power
plug from the outlet with a wet hand or allow the plug to get wet. Failure to use the supplied power
cord will void UL Certification and Warranty.
CAUTION!
INDOOR USE ONLY
.
Never exposed to direct sunlight, heat sources, or ambient air
temperature above 97°F (36°C) or below 50°F (10°C). Install indoors and keep unit away from
excessive humidity. Never expose to freezing temperatures. Ensure there is adequate clearance
around the unit to allow refrigeration system condenser to dissipate heat. Warmer environments
require more clearance around the unit. Minimum clearance around all surfaces of the machine is 2‐
inches. Installs where the ambient temperature exceeds 80°F, require a minimum of 4‐inches
clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Operating pressure must be 40 psi to 60 psi. Be aware
any of potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold‐water
supply only.
Feed water over 105° F (40°C) can damage the treatment components. Water block
devices and external leak detectors are strongly recommended. Locate the unit as close to the water
supply and the electrical connections as possible.
WARNING!
HIGH PRESSURE CO
2
GAS.
Use/Handle in accordance with all safety standards.
WARNING!
STORE UNIT EMPTY
.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
WL500
Water Treatment System
can be combined with RO Filtration Systems. RO will require a drain
connection. Refer to all applicable plumbing codes and standards in your area for these requirements
(air gap connections and back flow prevention may be necessary).