background image

 

WL500

 Manual 

                                                                           Page 55   Revision 4‐10‐2019 

 
 

In order for our Filters to perform as represented and to provide the best quality water possible, it is 
essential that Filters be replaced periodically. The frequency of Filters changes depends upon your 
water quality and your water usage. For example, if there is a lot of sediment and/or particles in 
your water, then you will have to change your Filters more frequently than a location with little to no 
sediment. Be sure to replace your Filters whenever you notice a decline in the performance, whether 
it is a drop‐in flow rate and/or pressure or an unusual taste in the water. 

 

4.

 

Flush thoroughly per Filters manufacturers’ recommendation with fresh water to drain.  
 

5.

 

Once flushed, install the Filters.  Following the flow direction on the Filters. 

 

NOTE:

  

Filters should not be flushed prior to 24 hours before installation to limit Microbial Growth.   

 

Sanitizing  
 

Sanitize using a household bleach solution or other approved cleaner throughout the cold and sparkling 
water circuits.  Follow all instructions on the sanitizer and flush with fresh water through the faucet 
until odor and taste is acceptable. 

 

       WARNING!  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

 

Always ensure proper ventilation and use proper personal protective equipment such as gloves and 
eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific requirements 
of each chemical product. Take all necessary precautions to prevent sanitizer from contacting eyes, 
clothing, and any other surfaces in could damage (carpets).  

 

 

6.

 

Remove the UV Cover Plate and set aside – 2 Screws. 

 

7.

 

Disconnect the UV Lamp harness and carefully remove the UV Lamp from the Quartz Sleeve. 

 

CAUTION!

  

UV SYSTEM IS FRAGILE. 

Never handle the UV System with bare hands.  UV Lamp and 

Quartz Sleeve must be free of oils and contaminants to ensure proper operation.

   

 

8.

 

Remove UV Sensor from the side of the Cold Tank/Quartz Sleeve Retaining Cap. 

 

9.

 

Unscrew Cold Tank/Quartz Sleeve Retaining Cap and remove the Quartz Sleeve.  This may require 
Top Cover to be removed to access properly and facilitate removal. 

 

10.

 

Mix ½ gallon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½ cap 
full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) with 1/2 gallon of water.  
Always ensure sanitizer is compatible with stainless steel and acetyl plastic. 

 

11.

 

Pour sanitizer solution into Cold Tank thru funnel or spout.  You may add concentrated sanitizer (½ 
cap bleach) directly into empty Cold Tank instead of premixing.  

 
 
 

 

Summary of Contents for WL500 - Sparkling

Page 1: ...ne Optional 1 8 NPT Female Thread to Compression Fitting Used to connect hose to drain fittings 1 Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage WARNING WL500 WATER T...

Page 2: ...ROPER PERSONAL PROTECTIVE EQUIPMENT Always ensure proper ventilation and use proper personal protective equipment such as gloves and eye protection when using chemicals Refer to Material Safety Data S...

Page 3: ...cur within one minute and the overload high limit will require manual reset if heater is turned on with an empty Hot Tank Fill the Cold Circuit with Sanitizer 17 Wait 10 seconds for the unit to perfor...

Page 4: ...least 5 minutes UV System Functional Test WARNING ULTRAVIOLET RADIATION Protect your skin and eyes against ultraviolet rays Never look directly at an operating UV light Disconnect before removing 24 D...

Page 5: ...9 F You can monitor the Hot Tank temperature by selecting the hot button when the Temp Display is RANGING Dispense a cup of hot water to ensure the temperature odor taste is acceptable WARNING VERY HO...

Page 6: ...or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to Compressio...

Page 7: ...emove Fitting from CO2 Line 7 Attach Water Inlet Valve 8 Add 1 2 drops of Bleach into the Sparkling Tank through the Sparkling Water Level Sensor line 9 Connect Drain Water line and fitting to the Spa...

Page 8: ...ank has a drain port and is the only tank that is open to atmosphere through the vent and faucet Prior to draining the Hot Tank turn the GREEN Compressor Heater Switch off O OFF and dispense 2 liters...

Page 9: ...kling water out of the Sparkling Chamber through the faucet of the WL500 Water Treatment System into the drip tray holds 1 5 liters or other container until only CO2 gas is dispensed The Sparkling Cha...

Page 10: ...areful not to touch UV Lamp surface as oils from your hands can cause dark spots and impact the performance of the system Always wipe off lamp with alcohol wipe or equivalent if needed Ensure lamp wir...

Page 11: ...he knock out in base cabinet up to the CO2 IN bulkhead fitting on the back of the WL500 Always secure the CO2 bottle with a chain or strap to prevent tipping 6 Establish 40 60 psi 0 5 gal min potable...

Page 12: ...Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around th...

Page 13: ...inuous flow of water is obtained Once a continuous flow is obtained release the dispensing button Cold Tanks are now full 5 Prime the Hot Tank Holding a container under the dispensing faucet press the...