Page 67 Revision 4‐10‐2019
9.
Move the
Waterlogic WL500
Water Treatment System
into its final operating position. Be sure that
a minimum of 2” clearance is maintained around both the sides and the back of the unit. This is
important to allow proper airflow and heat exchange of refrigeration system.
10.
Level unit using the adjustable feet to level if necessary. Never install on incline.
11.
Turn the GREEN Heater / Compressor switch on
I=ON
. Check for fan and
Compressor operation. This can be done by listening to the unit when the
GREEN Heater / Compressor switch on
I=ON
and/or is turned on and/or visibly
checking the fan. All tanks must be full.
12.
Change the Temp Display to Ranging to monitor the cold and hot water temperatures in the tanks.
After 15 minutes, the cold‐water should drop approximately one degree every 1‐1/2 minutes. The
hot water will heat rapidly and should reach set point in 10 minutes.
13.
When the unit has reached its Hot Temp Set Point, the heater will cycle off. When the unit has
reached its Cold Temp Set Point Temperature, the Compressor will cycle off.
14.
Once the unit is at the target temperature(s), sample the water to ensure water meets expectations
and additional rinsing or adjustment is not required.
15.
Regenerate the sparkling water by dispensing until a continuous flow of gas is obtained and release
to let the pump inject cold‐water (below 7.7°C / 46° F) into the chamber. This provides Premium
Sparkling Water. Sample the sparkling water to ensure it meets expectation.
16.
Check the unit for any leaks. External Leak Protection is always recommended.
17.
If you choose, reconfigure the temperature display back to the original Static setting and
Verify Default Program Settings (refer to Programming Instructions):
Cold Temp Set
= 41°F – Do not turn down as it may freeze the Sparkling Chamber.
Hot Temp Set
= 189°F – May need to be adjusted downward at high elevation.
Temp Display
= Static – Display’s set point temperatures
UV Timer
= 3 minute ‐ do not recommend using constant
F/C Set
= F ‐Fahrenheit Temperature Display
Language
= English
Flow Counter
= Disable by Using Filters Timer. DO NOT USE. See Filters Timer Note
Filters Timer
= NONE ‐ See Filters Timer – Programming Note below
Filters Life
= 00 Days. Ensure it displays “Days” to confirm Filters Counter is disabled.
Energy Saving Sleep Mode
= On – Unit comes set with Energy Saving Sleep Mode On
Filters Timer ‐ Programming Note:
Always enable the Filters Timer by selecting 3, 6, 9 Months or NONE. Enabling the Filters Timer will
disable the Flow Counter and the Filters Life will be displayed in Days rather than Gallons.
CAUTION!
NEVER ENABLE THE FLOW COUNTER.
A” NO WATER SUPPLY” Fault will occur if the Flow
Counter is Enabled.