DISPENSE TROUBLESHOOTING INDEX 

 

1.

 

Unit is dispensing water intermittently / irregularly 

2.

 

Run‐On 

3.

 

Low Flow of Water 

 
1.

 

Unit is dispensing water intermittently / irregularly 

 
 

Possible Reason 

Solution 

Ribbon Connectors are not 
fully engaged 

Verify ribbon connectors are properly engaged and fully seated in 
front PCB (Printed Circuit Board) to avoid intermittent / 
connectivity issues anytime the front Hatch Panel is accessed. 

 

Too much water pressure.  
Recommend 40‐60 psi for the 

WL500 Water Treatment 
System

 to operate properly. 

The correct input water pressure is critical to the performance of 
the unit to allow solenoids to open. 
 
Check water pressure at the inlet bulkhead with a water pressure 
gauge. 
 
Additional method of verification is to turn off water to unit and 
press the dispense button.  Does the solenoid open without water 
pressure to the unit?  Listen for solenoid to activate (not just the 
dispense button “click”) 
 
Adjust water pressure to 40‐60 psi. 

 

 

 