background image

EN

  Installation and user manual 

26

PROSOURCE

GYB 00416UT 

GYB 00816UT

Summary of Contents for GYB 00416UT

Page 1: ...EN Installation and user manual 26 PROSOURCE GYB 00416UT GYB 00816UT ...

Page 2: ...www aeg com Image 1 Main components of the complete system B E C D A ...

Page 3: ...1 ImagEs 6 7 8 9 10 11 12 4 1 2 3 5 Image 2 Parts description ...

Page 4: ...2 www aeg com 14 13 26 15 20 22 21 23 24 25 17 18 16 19 ...

Page 5: ...3 36 37 38 39 41 40 42 29 31 30 34 27 28 32 33 35 ImagEs ...

Page 6: ...4 www aeg com Image 3 Before installation ...

Page 7: ...5 Image 4 Overview Solo Situation ImagEs ...

Page 8: ...6 www aeg com Image 5 Overview Combi Situation ...

Page 9: ...7 Image 6 The tap Installed ImagEs ...

Page 10: ...8 www aeg com Image 7 The filter installed optional ...

Page 11: ...9 Image 8 Attach t piece to cold water supply Image 9 Place discharge connection on siphon ImagEs ...

Page 12: ...10 www aeg com Image 10 Attach bracket with 4 screws Image 11 Attach the safety valve to the mixing valve using the adapter and seal ...

Page 13: ...11 Image 12 Place discharge con nection on siphon ImagEs ...

Page 14: ...12 www aeg com Image 13 Attach discharge connection to siphon Image 14 Connect filter hose ...

Page 15: ...13 Image 15 Connect cold water hose to filter and pressure safety valve ImagEs ...

Page 16: ...14 www aeg com Image 16 Connect cold water hose to t piece and safety valve situation without filter ...

Page 17: ...15 Image 17 Connect cold water inlet boiler to pressure safety valve Image 18 Connect cold water inlet boiler to mixing valve ImagEs ...

Page 18: ...16 www aeg com Image 19 Connect boiling water hose boiler to boiling water inlet tap ...

Page 19: ...17 Image 20 Connect boiling water extension hose ImagEs ...

Page 20: ...18 www aeg com Image 21 Connect boiling water inlet tap to mixing valve ...

Page 21: ...19 Image 22 Connect cold water inlet tap to t piece ImagEs ...

Page 22: ...20 www aeg com Image 23 Connect warm water inlet tap to warm water supply ...

Page 23: ...21 Image 24 Connect warm water inlet tap to warm water outlet mixing valve ImagEs ...

Page 24: ...22 www aeg com Image 25 Use boiling water handle PUSH 1 2 ...

Page 25: ...23 Image 26 Use mixing handle 1 Image 27 Use mixing handle 2 OFF ON MIX ImagEs ...

Page 26: ...24 www aeg com Image 28 Built in dimensions 8 3 13 5 12 8 8 3 13 5 20 5 6 8 5 9 ...

Page 27: ...25 5 6 5 5 9 3 15 5 6 6 9 3 15 5 6 6 17 4 5 4 2 ImagEs ...

Page 28: ...reading to get the very best from it Visit our website to Get usage advice brochures trouble shooter service information www aeg com Register your product for better service www registeraeg com Buy Accessories Consumables and Original spare parts for your appliance www aeg com shop FOR PERFECT RESULTS CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised Service ...

Page 29: ... than described in this manual is seen as unintended use 1 2 general working principle This AEG appliance stores heats and provides boiling drinking water in addition to cold and warm water To supply boiling water cold water flows from the cold water supply to the boiler where it is heated to 100 C From the boiler the boiling water flows to the tap The cold water also flows from the cold water sup...

Page 30: ...ied instructions Refer to the separate manuals supplied with the other components for other relevant information The manufacturer is not responsible if an incorrect installation and or use causes injuries and damages Always keep the instructions with the appliance for future reference The information in this manual is subject to change without notice 2 2 Children and vulnerable people safety WaRNI...

Page 31: ...he instructions Failure to do so may affect the proper functioning of the product Unauthorized alterations to the appliance and technical modifications are not permitted 2 4 Water connection Install a pressure reducing valve if the water pressure of the water supply exceeds the maximum allowed water pressure of the pressure safety valve Refer to the section TECHNICAL INFORMATION for the maximum al...

Page 32: ...iling water Use the appliance only for its intended use as described in this manual Make sure the plug of the boiler and the power cable are not damaged when using the appliance Contact the manufacturer or an electrician if parts are damaged Clean the appliance regularly according to the instructions in this manual Unauthorized alterations to the appliance and technical modifications are not permi...

Page 33: ...dge must be replaced by a new one Refer to the manual of the filter for more information 3 1 main components appliance see image 1 Part Description A Boiler B Tap C Pressure safety valve with t piece hose bracket 4 screws and tie wrap D Mixing valve with extension hose for combi situation only E Filter with hose optional 3 2 main components boiler see image 2 Part Description 1 Cold water inlet bl...

Page 34: ...l 11 Boiling water handle with safety system 12 Mixer handle 3 4 main components pressure safety valve see image 2 Part Description 13 SealSeal 14 T piece 15 Bracket 16 Pressure reducing valve 17 Flow direction discharge water 18 Cold water outlet 19 Expansion vessel 20 Discharge connection 21 Screw funnel 22 Pressure relief device 23 Cold water inlet 24 Tie wrap 25 Screws 26 Cold water hose ...

Page 35: ...er inlet or outlet indicated by H 29 Warm water outlet indicated by MIX 30 Cold water inlet indicated by C 31 Cold water outlet 32 Seal 33 Cold water inlet 34 Temperature regulator 35 Extension hose 3 6 main components filter optional see image 2 Part Description 36 Bracket 37 Water inlet 38 Filter head 39 Cartridge 40 Filter hose 41 Water outlet 42 Flow meter ...

Page 36: ...onfiguration 2 Rinse all supplied hoses with water thoroughly 4 3 Installing the appliance step action 1 Determine which configuration you are going to install The appliance is available for 2 different configurations Solo situation see image 4 Combi situation see image 5 The solo configuration supplies only boiling water Warm water comes from the central boiler The combi configuration supplies bo...

Page 37: ...p 24 according to the instructions supplied with the pressure safety valve Place the pressure safety valve C with the discharge connection 20 on the siphon see image 9 Mount the bracket 15 with the four screws 25 to the wall of the kitchen cabinet see image 10 If you install the combi configuration Mount the pressure safety valve according to the instructions supplied with the pressure safety valv...

Page 38: ... the boiler 1 to the cold water outlet of the mixing valve 31 see image 18 NOTICE The cold water inlet of the boiler 1 bears a blue label 10 Connect the boiling water If you install the solo configuration Connect the boiling water outlet of the boiler 2 to the boiling water inlet of the tap 10 see image 19 NOTICE The boiling water outlet of the boiler 2 bears a red label The boiling water inlet of...

Page 39: ...not insert the plug of the boiler into the earthed AC wall socket First fill the system with cold water according to the instructions in this section To fill the appliance with cold water step action 1 Make sure all connections are tightened properly to prevent leakages 2 If the mixing valve is D installed set the temperature with the temperature regulator 34 3 Make sure the valve 16 on the pressu...

Page 40: ...le 11 Turn the handle counterclockwise to open the valve Keep the valve open until the system is flushed with one boiler fill 4 or 8 litres 4 Give all user manuals to the end user of the appliance The appliance is now fully installed and ready for daily use 5 1 Important operation information Read and follow all instructions in the SAFETY INFORMATION section Refer to the separate manuals supplied ...

Page 41: ...e the boiling water tap The handle closes automatically To get the best results for example to prepare coffee or tea it is necessary to let the first water flow This allows removing air bubbles that are in the water and tend to form a layer of foam on the preparation 5 3 Using the mixed water tap WaRNINg Temperature of water delivered by mixed water tap can reach 65 C and can be hot To open and cl...

Page 42: ...blocked Every 6 months Replace the filter cartridge Annually or if the appliance is not used for 4 weeks or more 7 1 Important trouble shooting information Read and follow all instructions in the SAFETY INFORMATION section Refer to the separate manuals supplied with the other components for other relevant troubleshooting information Refer to solutions provided in this section before you contact Cu...

Page 43: ...ontact your water supplier if problems are not solved No boiling water from tap The boiler is turned off The plug is disconnected The earth leakage protection switch is in the open position Press the ON OFF button 5 for min 0 5 seconds Connect the plug of the boiler 3 to the earthed AC wall socket Make sure the earth leakage protection switch is in closed position No warm water from tap The boiler...

Page 44: ...ant other technical information Refer to the separate manuals supplied with the other components for other relevant technical information 8 2 general data Name aEg Prosource Ambient temperature 4 38 C Humidity range 25 85 relative humidity RH Maximum operation height 2000 m Protection grade IPX4 8 3 Electrical data 4 litre 8 litre Connection Earthed AC wall socket Voltage supply 230 V AC 50 Hz Max...

Page 45: ...ombi configuration Approx 3 9 l min Flow rate mixed water at 0 15 MPa 1 5 bar flow pressure Solo configuration n a Combi configuration Approx 3 3 l min Flow rate mixed water at 0 4 MPa 4 bar flow pressure Solo configuration n a Combi configuration Approx 5 8 l min Temperature regulation Thermostatic mixing valve Pressure safety Depends on local or national situation Heating time from 10 C to 99 C ...

Page 46: ......

Page 47: ......

Page 48: ...www aeg com shop 12400 A 242015 ...

Reviews: