background image

 
 
 

Publication PB 0175 

Issue 2

  

 
 
 
 

IP55 ingress protection, variable speed high-flow pump 

Installation and operating instruction 

 
 
 

 

 

Drive/s: Issue 

EPROM: N/A 

Pumphead/s: 603R 

Issue 

 

 

 
 
 
 

 

 

 

 

 

 

 

Contents

 

Declarations 

 .................................................... 

Page 

2

 

604S/R

 

Summary of Contents for 604S/R

Page 1: ...lication PB 0175 Issue 2 IP55 ingress protection variable speed high flow pump Installation and operating instruction Drive s Issue 4 EPROM N A Pumphead s 603R Issue 1 Contents Declarations Page 2 604...

Page 2: ...one pump it complies with Machinery Directive 89 392 EEC and EN60204 1 Low Voltage directive 73 23 EEC and EN61010 1 EMC Directive 89 336 EEC and EN50081 1 50082 1 Responsible person A S Balding Manag...

Page 3: ...nty Watson Marlow Limited warrants subject to the conditions below through either Watson Marlow Limited its subsidiaries or its authorised distributors to repair or replace free of charge including la...

Page 4: ...ng that peristaltic pumps are self priming and will hold their prime up to several metres so there may be no need for non return or foot valves nor for the loading valves required on many other kinds...

Page 5: ...el Alternative connectors are supplied to screw into the entry point gland One accepts 20mm rigid or flexible conduit and the other accepts three core 0 75 square millimetre PVC smooth sheathed mains...

Page 6: ...eed control ratio of the 604S R is 50 1 giving a speed range from approximately 4rpm to its rated maximum speed of 165rpm Flow rates The flow rates given below were obtained using Watson Marlow 3 2mm...

Page 7: ...ly degreased slide the rotor into position The rotor is attached to the drive spindle via a split collet and it is important that the rotor retaining screw is fully tightened a torque of 13Nm to preve...

Page 8: ...ty controlled to our own specifications We recommend Marprene tubing whenever it is chemically suitable The Product Codes for the range of tubing suitable are listed below Tubing for 603R pumphead Bor...

Page 9: ...required Guard switch and magnet Grommet MR 0258M SW 0139 MRA0161A GR 0008 and follower roller Drive spares Direction switch MN 0690S Vertical gasket 4 required MR 0506H Wiring harness MR 0771S Gasket...

Page 10: ...operation If the pump needs cleaning use a cloth dampened with water and mild detergent Do not use strong solvents If harmful liquids are spilled on to the pump first switch off the pump and isolate...

Page 11: ...Page 11 Outline drawing...

Page 12: ...ion 5 4 2 5 2 Serial number 5 4 1 I hereby confirm that the equipment specified has not pumped nor come into contact with any toxic or hazardous substances 5 3 Details of substances pumped Signed 5 3...

Reviews: