background image

OPERATION MANUAL

SHP-SHP-140ERC

SHP-SHP-180ERC

SPLIT AIR TO WATER HEAT PUMPS

LAN

H E A T   P U M P S

Summary of Contents for S-THERM+ SHP-140ERC

Page 1: ...OPERATION MANUAL SHP 140IRC SHP 140ERC SHP 180IRC SHP 180ERC SPLIT AIR TO WATER HEAT PUMPS LAN H E A T P U M P S ...

Page 2: ......

Page 3: ...e of heat pump connection to the LAN network Connection of heat pump is made with a standard Ethernet cable with RJ45 connector which is connected to any free LAN port of the main router see Fig 1 Factory default setting of the heat pump is the automatic network connection using DHCP protocol After connection to the network heat pump asks DHCP server this function is mostly done by the router for ...

Page 4: ...g 2 Heat pump IP address Web browser will display the home page of the web interface Web interface is divided into two sections left column shows always main navigation buttons the right section shows contents Main navigation buttons have these functions Homepage display Heat pump control page display Page with the survey of measured temperatures display Heat pump settings page display ...

Page 5: ...escription of icons Indication of energy distribution tariff Meaning of the colors green low tariff red high tariff Indication of heat pump status Meaning of the colors grey switched off green waiting red heating blue cooling violet defrosting Water temperature in the solar collector Temperature of domestic hot water in the tank ...

Page 6: ...the outside temperature the reference room temperature and the swimming pool temperature are shown on the homepage The page is updated automatically every 15 seconds 2 2 Heat pump control page This page gives the possibility to switch on the heating or cooling mode to switch the heat pump off or to start the evaporator defrosting manually Fig 4 Heat pump control page For more details to the heatin...

Page 7: ...isplays the current temperature of the air water refrigerant and possibly also pressures in the refrigerant circuit and from them derived evaporation temperatures Fig 5 Page with a survey of measured temperatures The page is updated automatically every 15 seconds ...

Page 8: ...ration parameters of the heat pump and to the selection of language for the web interface Fig 6 Heat pump settings page Displayed buttons are used for the setting of the following item groups Comfort settings Priority settings Operation parameter settings Equitherm settings LAN settings ...

Page 9: ...ide temperature without the necessity to change equitherm settings or other heat pump settings You simply select how many degrees you want to increase or decrease the inside temperature than usually Individual parameters can be changed after clicking on them and inputting the value from the keyboard or changed using buttons and Fig 7 Comfort settings ...

Page 10: ...igher priority The circuit with a lower priority will be heated only after heating that one with a higher priority If some heating circuit has a zero priority this circuit will be eliminated from the heating process Furthermore it is possible to define where the heat from solar collectors should be directed Fig 8 Priority settings Description of icons Priority for domestic hot water DHW tank Prior...

Page 11: ...clicking on them and inputting the value from the keyboard or changed using buttons and Fig 9 Operation parameter settings Temperature settings Start temperature for DHW if the temperature in DHW tank drops below the set temperature the heat pump starts heating DHW tank Stop temperature for DHW when the temperature in DHW tank rises during heating above the set temperature the heat pump stops heat...

Page 12: ...temperatures when individual circuits are heated regardless of RCS tariff or on the other side if the tariff is respected Temperatures are set separately for DHW circuit for heating water and for swimming pool If for example the outside temperature drops to the values when heating stop during high tariff should have impact on the thermal comfort in the house then it is possible to ignore the tarif...

Page 13: ...because each house has a different thermal loss radiator surface etc so that requested thermal comfort in the house can be kept in all weather conditions The curve is defined by four points for four different outside temperatures are determined four different temperatures of heating water for radiators and four different temperatures of heating water for underfloor heating these temperatures are u...

Page 14: ... This page is used for changing settings of heat pump connection to LAN network It contains the same settings which are accessible from heat pump operation panel LAN settings menu more details in chapter Fig 11 LAN settings ...

Page 15: ...13 2 4 6 Remote supervision settings This page is used for remote supervision settings if the heat pump is connected via router to the internet Fig 12 Remote supervision settings ...

Page 16: ...possibility to enter up to 16 authorized telephone numbers which can control the heat pump from the mobile phone or which can receive an information message in case of any fault or event Furthermore it is possible to enter so called SMS password which can be used for heat pump control from any telephone line For more details see chapter ...

Page 17: ...8 Language selection This page is used for the selection of the web interface language Fig 14 Language selection 3 Conclusion The manufacturer reserves the right for changes in this manual without prior notice ...

Page 18: ...ufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purky ova 45 612 00 Brno Czech Republic www nepa cz Toll free info line 420 800 100 285 ...

Reviews: