WL400
Manual Page 60
–
Revision: 10-23-2019
INSTALLATION PROCEDURES
Safety and Installation Guidelines
Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met
when installing
Waterlogic
Equipment. Only qualified service technicians should attempt
installation and service of
Waterlogic
Equipment.
WARNING!
ELECTRICAL SHOCK HAZARD.
Always unplug (isolate from power supply) to prevent
electrical shock except where electrical tests are specified.
WARNING!
IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK.
Connect to a 15 amp 120V 60Hz properly grounded outlet (GFI is recommended). Ensure polarity is
correct and always use a 3-prong outlet. Consult a qualified electrician if you have any questions.
WARNING!
USE ONLY Waterlogic SUPPLIED POWER CORD.
Locate system within 5 feet of
power supply. Never use an extension cord or adapter. Do not use a damaged power cord or plug.
Keep power cord out of heavy traffic areas and away from heat sources. Do not, under any
circumstances, remove ground prong or alter the power cord. Never pull the power plug from the
outlet with a wet hand or allow the plug to get wet. Failure to use the supplied power cord will void
UL Certification and Warranty.
CAUTION!
INDOOR USE ONLY
.
Never expose to direct sunlight, heat sources, or ambient air
temperature above 100°F (37°C) or below 35°F (2°C). Install indoors and keep unit away from
excessive humidity. Never expose to freezing temperatures. Ensure there is adequate clearance
around the unit to allow refrigeration system condenser to dissipate heat. Warmer environments
require more clearance around the unit. Minimum clearance around all surfaces of the machine is 2-
inches. Installs where the ambient temperature exceeds 80°F, require a minimum of 4-inches
clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Operating pressure must be 40 psi to 60 psi. Be aware
any of potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold
water supply only.
Feed water over 100° F (37°C) can damage the treatment components. Water
block devices and external leak detectors are strongly recommended. Locate the unit as close to the
water supply and the electrical connections as possible.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
Pre-installation and sanitization procedures as prescribed in this manual must be performed before
installing the
WL400
Water Treatment System
Always install indoors and place the
Waterlogic WL400
Water Treatment System
on a firm, flat and
stable surface.
Summary of Contents for WL400 Series
Page 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Page 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Page 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Page 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Page 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...