WL400
Manual Page 13
–
Revision: 10-23-2019
SERVICE REQUIREMENTS
WARNING!
Read and understand the contents of this manual before attempting to service
WL400. Failure to follow the instructions in this manual could result in death, serious
personal injury, or severe property damage. Only trained and qualified technicians should
attempt to install, maintain, or service Waterlogic Equipment.
1.
Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD.
Unplug before inspection and service.
2.
Waterlogic
recommends changing the UV Lamp Assembly and Wiring Harness must be replaced
every 6 months.
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS.
Lamps are considered Hazardous Waste and must
be disposed of accordingly. Refer to Product MSDS sheet for details.
3.
Clean the Quartz Sleeve that surrounds the UV lamp with a non-abrasive cloth, descaling solution,
or ultrasonic bath if needed when changing UV Lamps.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV lamp or Quartz Sleeve with bare
hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4.
Inspect the Quartz Sleeve O-ring for wear or damage and replace as necessary.
5.
Ensure there is adequate (minimum of 2”) clear
ance around the unit and clean the condenser grill
and compressor fan to provide efficient cooling system operation.
6.
Sanitize the Cold Tank per instructions in the Pre-Installation procedures.
7.
Clean and sanitize external surfaces of the unit. Use soap and water or chemicals that are
compatible with ABS plastic and will not damage or degrade the product surfaces.
8.
Remove and clean the Faucet. Replace as needed.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper personal
protective equipment such as rubber gloves and eye protection is required.
13UV Lamp Assembly
Part Number CT-2090-C WLCP Part Number 10-8075
Summary of Contents for WL400 Series
Page 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Page 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Page 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Page 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Page 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...