WL400
Manual Page 78
–
Revision: 10-23-2019
13.
Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary
depending on water conditions).
14.
Place a pitcher, catch basin or other container under the faucet of the
WL400
Water Treatment
System.
15.
Flush the Hot Tank until water runs clear.
16.
Once clear water dispenses from the faucet the Hot Tank has been descaled. Always ensure unit
is performing to the customer’s satisfaction.
WARNING!
HOT WATER HAZARD. WL400 Water Treatment System produces VERY HOT
WATER up to 203°F (95°C). Water above 125°F (52°C) can cause severe burns or scalding.
Hot
water should be dispensed carefully into insulated container to avoid injury.
CAUTION
!
MUST
REPLACE HOT TANK 3-5 YEARS DEPENDING ON USAGE
. The hot tank and
its controls must be replaced a minimum of every five years to ensure efficient and dependable
operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all panels, protective
covers, and fasteners after servicing equipment. Failure to do so could result in severe personal
injury and will void the certifications and warranty of the equipment
.
Summary of Contents for WL400 Series
Page 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Page 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Page 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Page 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Page 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...