WL400
Manual Page 79
–
Revision: 10-23-2019
COLD WATER TROUBLESHOOTING INDEX
1.
Cold Water is not Cold (41
°
+/- 5
°
F)
1.
Cold Water is not Cold (41
°
+/- 5
°
F)
Possible Reason
Solution
No power or refrigeration
elements
Check that the Green
Heater/Compressor switch is on.
I
= ON
Tank has run out of cold water.
Wait for cold tank to chill water to temperature prior to
dispensing more cold water.
A greater capacity of
Waterlogic
Water System is available.
Cold Water Thermostat
Check continuity of thermostat with multimeter. Replace
thermostat as required.
Refrigerant has run out
Run compressor for at least ten minutes. If condenser is not
warm, then refill the refrigerant.
Compressor problem
If compressor is not running, repair or replacement is
needed.
Summary of Contents for WL400 Series
Page 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Page 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Page 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Page 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Page 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...