WL1000GF MAX
Manual
Page 20 Revision 10-7-2017
FAUCET SERVICING
It is necessary to descale and sanitise the faucets during any service. This is to remove any
minerals or contaminants that may have built up and to preserve the longevity of the
WL1000GF MAX
1. Remove the gravity faucets from the WL1000GF MAX and separate the body from the head of
the faucet by undoing the retaining nut.
2. Once disassembled from the body, check the rubber boot has no signs of any debris or
damage. There is a chance that carbon deposits from the filter can get caught up into the
body and cause the rubber boot not to seat correctly onto the housing. The housing itself will
also need to be checked for any signs of contaminants or
damage to ensure a good seal
when water is dispensed.
3. Ensure both the body and the
head of the faucets are
thoroughly cleaned before
reassembly, if required, change
the rubber boot.