4.
Mix 60ml of Aquadosa sanitiser as per directions or see manufactures instructions to other
sanitiser products. Always ensure sanitiser is compatible with stainless steel and acetyl plastic.
WARNING!
Use Personal Protective Equipment. Gloves and Eye Protection Required. The first 2
or 3 gallons of water will contain concentrated sanitiser. Use extreme care!
5.
Start filling the Reservoir Tank with clean water, after approximately ½ full add in the sanitiser.
Continue to fill the Reservoir Tank with water until full.
6.
The Circulation Pump will turn on when adding water to the Reservoir. Allow the water with
sanitiser to circulate in the Reservoir Tank for 10 minutes.
7.
Drain the water with sanitiser by removing the Drain Valve Caps at rear of
WL1000GF MAX
.
Do not reinstall the Drain Valve Nuts at this time.
8.
With a minimum of 10 litres of clean water, rinse out the Reservoir Tank to
remove all sanitiser.
9.
Clean Reservoir Lid with Dish Soap and Water. Rinse thoroughly.
10.
Install the Hose Adaptor fitting that is packed in the accessories bag found in the drip
tray onto the water inlet fitting on the back of the machine.
CAUTION!
DO NOT OVERTIGHTEN
11.
Install the metal stand-off plate from the accessories bag and install over
the water inlet. Connect a section of the ¼” plastic tubing from the water
supply line into the hose adaptor fitting at the back of the unit.
CAUTION!
DO NOT TURN ON THE WATER YET
CAUTION!
FILTER FLUSHES REQUIRED.
WL1000GF MAX Water Treatment Systems
are not supplied with filters. Filters should be
configured to optimize your system. Filters need to be configured and specified to do the job
given the local water conditions, usage, maintenance schedule, and placement restrictions.