WL1000GF MAX
Manual
Page 46 Revision 10-7-2017
DISPENSING TROUBLESHOOTING INDEX
1. Hot Water flow, Cold Water does not flow
2. Cold Water flows, Hot Water does not flow
3. Low Flow of Water
4. Restricted Flow of Hot Water
5. No Water Will Dispense from Unit
6. Small Amount of Water Periodically Dispenses from Faucet Automatically
7. Dispense Buttons Stick
Included in this section are the Draining Instructions.
1.
Hot Water flows, Cold Water does not flow.
Possible Reason
Solution
Cold tank frozen
Disconnect power supply for one hour to allow tank to
defrost.
Flush the cold-water system.
Check that the cold thermistor settings are correct Cold
Water Temperature – Factory Set Point 5°C (41°F)
(Adjustable 3°- 7° C (37°F - 45°F).
Mechanical Water Outlet
Faucet Valve
Check that the mechanical water outlet faucet valve is
operating correctly and that water flows through it.