WL1000GF MAX
Manual
Page 48 Revision 10-7-2017
4.
Restricted Flow of Hot Water
Possible Reason
Solution
Partially closed water supply
valve to the unit.
Open water supply valve.
Hot Tank outlet hole is scaled
over.
Remove outlet tube from Hot Tank to faucet. Add descaler
to Hot Tank.
Tubing is creased or has a
“kink” in it.
Inspect and replace tubing as necessary.
Faucet nipple screen mesh has
obstruction(s)
Unscrew faucet nipple from faucet and remove any
obstruction(s) from screen mesh.
Exhausted Filter
Replace the Filter
Solenoid connection to the
Display PCB
Turn power off; unplug the unit and visually inspect solenoid
connections into the Display PCB. Verify the soldering points
on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Solenoid Valve is
Malfunctioning
Inspect valve components for proper function. Replace as
necessary.
5.
No Water Will Dispense from Unit
Possible Reason
Solution
Closed water supply valve
Open the water supply valve.
The unit is not properly
plugged into electrical outlet
Check electrical outlet connection, or for blown circuit
breaker.
Red Heater and Compressor
button on unit is in the off
position
Turn Red Heater and Compressor switch on.
I = ON
Fuse Blown
Replace the Fuse as needed.
Water is present in the bottom
tray, causing the leak
detection to trigger.
.
Remove the top cover and front panel. Tip the unit slightly
to drain, dry bottom tray completely.
Exhausted Filter / Membrane
Replace filters / membrane as needed.