Electrical work
21.11.2015
46 / 76
Z20469
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
9
Electrical work
Before carrying out electrical work:
Warning! Risk of electric shock!
Install circuit breakers for personal protection.
Any work on the electrical equipment of the machine shall only be performed
by professional electricians!
For the power lines, use standard cables of sufficient capacity. Otherwise
there is a risk of short circuits, overheating or fire.
When installing power lines, do not apply tension to the cables. Loosened
connections pose a risk of cables slipping from terminals or breaking; this can
result in overheating or fire.
Should it be necessary, disconnect all feed lines from the house fuse box.
Risk of total loss!
The device may only be switched on when the hydraulic circuits are completely
filled and vented, and all electrical connections are properly.
9.1
Electrical installation
Follow the wiring diagram!
The installation must be performed by an accredited professional. He is also re-
sponsible for the proper installation according to regulations and initial commis-
sioning.
For electrical installation, the regulations of VDE/EN as well as of EVU must be ob-
served.
For wiring, standard lines must be used.
Mains connection cable, if not connected to fixed installation:
Type H05VV-F.
Connection cables 230 / 400 V and remote cables / sensor cables must be in-
stalled with separate cables.
Minimum diameter of connection cables 1.5 mm².
Attention: Terminals in connection terminal max. 4 mm². Vacant terminals may not
be used as support terminals for additional wiring.
Please note:
All plug connections used in the heat pump control may not be connected or
disconnected under voltage – disconnect mains voltage.
Before accessing connection terminals, all power supply circuits must be in-
terrupted.
The relay circuit board (WWPR) may only be connected or removed by pro-
fessionals.