Connection diagrams
21.11.2015
72 / 76
Z20469
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
18.7
Description of the parts in the connection diagram
No.
Description
1
underfloor heating system
2
heat pump
3
indoor module
4
outdoor module
5
flexible connectors
6
amature group for rinsing and bleeding
7
ball valve with integrated dirt trap
8
flow rate control
9
ground water pump
10
plate heat exchanger
11
motor-powered switch ball valve (uninterruptible)
12
optimized thermo storage (charging storage)
13
optimized thermo storage (backflow array storage)
14
temperature sensor
15
radiators or convectors
16
bronze pump
17
pressure reducer
18
backflow preventer
19
relief valve
20
valve, actuating variable 1 to 2 Kelvin
21
membrane expansion tank for potable water systems
22
membrane expansion tank with shut-off fitting
23
domestic cold water
24
domestic hot water (DHW)
25
circulation
26
potable water heater
27
250l storage for domestic hot water
28
air separator with bleeder
29
pressure bypass valve
30
pressure controlled circulation pump
31
fill and drain valve
32
circulation pump
33
air separator with bleeder, manometer and relief valve
34
safety group
35
relief valve with bleeder and manometer
36
tacosetter for hydraulic alignment
37
charging storage 250 liter
38
swimming pool
039
motor-powered mixing valve
40
membrane expansion tank solar with shut-off fitting
41
heat source module
42
heat source module natural cooling
43
motor-powered switch ball valve, uninterruptible (heating and cooling)
44
2nd heat generator
45
non-return valve
46
regulating valve
47
dirt trap
48
motor-powered switch valve