Installation
21.11.2015
20 / 76
Z20469
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
6
Installation
Installation of the heat pump must be performed on a flat and horizontal sur-
face.
We recommend a concrete base.
Recommendation:
Wall clearance left, right and on top must be at least 400 mm.
Wall clearance in rear must be at least 200 mm.
Wall clearance in front: at least 1.000 mm
Figure 6: Recommendation - wall clearances
6.1
Environmental conditions for installation
The room must be dry. Room temperature should be between
+10 °C and +30 °C.
To facilitate maintenance, the use of a base plate is recommended. The housing
frame is to be completely supported. If support is only provided at points, operat-
ing noise increases. To compensate for minor unevenness, we recommend use of
an approx. 10 mm thick rubber mat. Acoustics in installation rooms with rigid walls
can noticeably increase operating noise.
Counter measure: acoustic insulation of one of the opposite wall or ceiling surfac-
es.