Technical data
21.10.2015
45 / 60
Copyright
2014 by: WATERKOTTE GmbH. Subject to changes.
11
Technical data
Basic Line Ai1 Air / Basic Line BS 7010
5006.5
5010.5
Heating capacity (A-7/W35)
kW*
6.6
7.1
Power consumption
2.8
2.8
COP (A-7/W35) EN14511
2.4
2.6
Heating capacity (A2/W35)
kW*
7.5
10.8
Power consumption
2.3
2.8
COP (A2/W35) controlled (EN14511)
3.54
(controlled at 4.5 kW)
3.55
(controlled at 6.7 kW)
Heating capacity (A7/W35)
kW*
8.6
12.3
Power consumption
2.3
2.9
COP (A7/W35) controlled (EN14511)
4.61
(controlled at 5.5 kW)
4.49
(controlled at 8.0 kW)
Cooling capacity (A35/W7)
kW*
-
7.8
Power consumption
-
3.0
COP (A35/W7) EN14511
-
2.5
Cooling capacity (A35/W18)
kW*
-
10.6
Power consumption
-
3.2
COP (A35/W18) EN14511
-
3.3
Heating water flow rate (∆t=5K ) at 8.0 kW
m³/h
1.0 (at 6.0 kW)
1.4 (at 8.0 kW)
Air volume flow (max)
m³/h
2800
7000
Application limit
A-15/W45; A-7/W50; A0/W55
Compressor
rolling piston
Refrigerant
R410A
Noise level at 5 m distance (outdoor module) free field
dB(A)
33
47
Sound level power
dB(A)
58
69
Electrical data
Electrical power supply
220-240V, 1~, 50 Hz
220-240V, 1~, 50 Hz
Electrical power supply - Electrical resistance heating
(Power supply selectable
220-240V, 1~, 50 Hz
380-415 V, 3~, 50 Hz
220-240V, 1~, 50 Hz
380-415 V, 3~, 50 Hz
Max. operating current
A
18.5
18.5
Customer-supplied main fuse
C 25 A
C 25 A
Customer-supplied control fuse
A
10
10
Current consumpt. max., electr. resistance heating (230 V)
A
26.1
26.1
Current consumpt. max., electr. resistance heating (400 V)
A
8.7
8.7
Electrical resistance heating
kW
6
6
Customer-supplied main fuse: Electrical resistance heating
(220-240 V)
A
B 32 A
B 32 A
Customer-supplied main fuse: Electrical resistance heating
(380-415 V
A
B 16 A
B 16 A
Dimensions, weight, connections
Refrigerant volume
kg
1.9
3.
Weight outdoor module
kg
100
120
Weight indoor module (Basic Line Ai1 Air)
kg
145
145
Weight hydraulic station (Basic Line BS Hyd 5010)
kg
39-40
39-40
Volume tank (Basic Line Ai1 Air))
l
170
170
Refrigerant lines (outdoor module)
16 / 10 mm
16 / 10 mm
Heating connections (hydraulic station)
1¼“a
1¼“a
Dimensions (outdoor module) W x H x D
mm
1235x855x510
1055x1194x460
Dimensions (indoor module) W x H x D (Basic Line Ai1 Air) mm
600x1850X650
600x1850X650
Dimensions hydraulic station W x H x D (Basic Line BS
Hyd 5010)
mm
743x750x303
743x750x303
1)
Tolerances as per EN 12900 apply to the performance data listed