identified by “SF” in the
upper left hand corner of the
screen. Use the Up and Down
buttons to adjust the value
from 0 to 50% as needed.
9. Fixed Reserve Capacity (Display Code RC)
Press the Extra Cycle button. Use this display to set the
Reserve Capacity. This setting specifies a fixed volume that
will be held as a reserve. The reserve capacity cannot be set
to a value greater than one-half of the calculated system
capacity. The reserve capacity is a fixed volume and does
not change if the unit capacity or feed water hardness are
changed. This option setting
is identified by “RC” in the
upper left-hand corner of
the screen. Use the Up and
Down buttons to adjust the
value as needed.
10. Day Override (Display Code DO)
Press the Extra Cycle button. Use this display to set the Day
Override. This setting specifies the maximum number of days
between regeneration cycles. If the system is set to a timer-
type control, the day override setting determines how often
the system will regenerate. A metered system will regenerate
regardless of usage if the days since last regeneration cycle
equal the day override setting. Setting the day override
value to “OFF” disables this
function. This option setting
is identified by “DO” in the
upper left hand corner of
the screen. Use the Up and
Down buttons to adjust the
value as needed.
11. Regeneration Time
Press the Extra Cycle button. Use this display to set the
Regeneration Time. This setting specifies the time of day
the control will initiate a delayed, manually queued, or
day override triggered regeneration. This option setting
is identified by “RT” in the
upper left hand corner of the
screen. Use the Up and Down
buttons to adjust the value as
needed.
5. Unit Capacity (Display Code C)
Press the Extra Cycle button. Use this display to set the Unit
Capacity. This setting specifies the treatment capacity of
the system media. Enter the capacity of the media bed in
grains of hardness when configuring a softener system, and
in the desired volume capacity when configuring a filter
system. This option setting is identified by “C” in the upper
left hand corner of the screen. The Unit Capacity parameter
is only available if the
control type has been set to
one of the metered options.
Use the Up and Down
buttons to adjust the value
as needed.
6. Feedwater Hardness (Display Code H)
Press the Extra Cycle button. Use this display to set the Feed
Water Hardness. Enter the feed water hardness in
grains per unit volume for softener systems, or 1 for filter
systems. This option setting is identified by “H” in the
upper left hand corner of the screen. The feedwater
hardness parameter is only
available if the control type
has
been set to one of the
metered options. Use the Up
and Down buttons to adjust
the value as needed.
7. Reserve Selection (Display Code RS)
Press the Extra Cycle button. Use this display to set the Safety
Factor. Use this display to select the type of reserve to be
used in your system. This setting is identified by “RS” in the
upper left-hand corner of the screen. The reserve selection
parameter is only available if the control type has been set
to one of the metered options.
There are two possible settings.
8. Safety Factor (Display Code SF)
Press the Extra Cycle button. Use this display to set the
Safety Factor. This setting specifies what percentage of
the system capacity will be held as a reserve. Since this
value is expressed as a percentage, any change to the
unit capacity or feedwater hardness that changes the
calculated system capacity will result in a corresponding
change to the reserve volume. This option setting is
9
Master Programming Mode
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Range: 1-999,900 grain capacity
Range: 4-199 hardness
FS
Safety Factor
rc
Fixed Reserve Capacity
Range: 0-50%
Range: 0-half the calculated
225
Range: Off-99 days
Summary of Contents for 6200 SXT
Page 1: ...6200 SXT Upflow Control Valve for Water Conditioning and Treatment Purposes Service Manual...
Page 21: ...Wiring Diagram 21...
Page 22: ...6200SXT Upflow Brining Rates 22 6200SXT Upflow Brining Rates with Water 20 PSI Regulated Cap...
Page 29: ...29 6200 SXT Valve Dimensional Drawings All dimensions are in Inches mm...
Page 35: ...35...