5. Press the Up button. Use
this display to view the
Volume Used since the
last regeneration cycle.
This option setting is
identified by “VU” in the
upper left hand corner of
the screen.
6. Press the Up button. Use
this display to view the
Reserve Capacity. This
option setting is identified
by “RC” in the upper
left hand corner of the
screen.
7. Press the Up button. Use
this display to view the
Software Version. This
option setting is identified
by “SV” in the upper
left hand corner of the
screen.
8. Press the Extra Cycle button to end Diagnostic
Programming Mode.
12
Diagnostic Programming Mode
Diagnostic Programming Mode Steps
1. Press the Up and Extra Cycle buttons for five seconds
while in service.
2. Use this display to view
the current Flow Rate.
This option setting is
identified by “FR” in the
upper left hand corner
of the screen.
3. Press the Up button. Use
this display to view the
Peak Flow Rate since
the last regeneration
cycle. This option setting
is identified by “PF” in the
upper left hand corner of
the screen.
4. Press the Up button. Use
this display to view the
Hours in Service since
the last regeneration
cycle. This option setting
is identified by “HR” in the
upper left hand corner of
the screen.
Diagnostic Programming Mode Options
Abbreviation
Parameter
Description
FR
Flow Rate
Displays the current outlet flow rate
PF
Peak Flow Rate
Displays the highest flow rate measured since the last regeneration
HR
Hours in Service
Displays the total hours that the unit has been in service
VU
Volume Used
Displays the total volume of water treated by the unit
RC
Reserve Capacity
Displays the system’s reserve capacity calculated from the system
capacity, feed water hardness, and safety factor
SV
Software Version
Displays the software version installed on the controller
NOTES:
Some items may not be shown depending on timer configuration.
The timer will exit Diagnostic Mode after 60 seconds if no buttons are pressed.
Press the Extra Cycle button to exit Diagnostic Mode at any time.
Summary of Contents for 6200 SXT
Page 1: ...6200 SXT Upflow Control Valve for Water Conditioning and Treatment Purposes Service Manual...
Page 21: ...Wiring Diagram 21...
Page 22: ...6200SXT Upflow Brining Rates 22 6200SXT Upflow Brining Rates with Water 20 PSI Regulated Cap...
Page 29: ...29 6200 SXT Valve Dimensional Drawings All dimensions are in Inches mm...
Page 35: ...35...