Job Number: __________________
Model Number: ________________
Water Hardness: ___________________ ppm or gpg
Capacity Per Unit: ______________
Mineral Tank Size: ___________ Diameter: ___________ Height:
Salt Setting per Regeneration: ___________________________________
__________
1. Type of Timer:
A. Day Override B. Meter Initiated
2. Upflow
3. Meter Size:
A. 3/4” Std Range (125 - 2,100 gallon setting)
B. 3/4” Ext Range (625 - 10,625 gallon setting)
C. 1” Std Range (310 - 5,270 gallon setting)
D. 1” Ext Range (1,150 - 26,350 gallon setting)
E. Electronic________ Pulse Count ________ Meter Size
4. System Type:
A. Twin Tank (Softener)
B. Cabinet (Softener)
C.
Filter
5. Timer Program Settings:
A. Brine and Slow Rinse: _________________________ Minutes
B.
Backwash:
__________________________________ Minutes
C. Rapid Rinse: _________________________________ Minutes
D. Brine Tank Refill: ______________________________ Minutes
6. Drain Line Flow Control: ____________ gpm
7. Brine Line Flow Controller: __________________ gpm
8. Injector Size#: _____________________
Valve Specifications
Valve material
Fiber-reinforced ploymer
Inlet/Outlet
3/4” - 1” NPT, BSP, Sweat
Cycles
Up to 5 cycles
Flow rates (50 psi Inlet) - Valve Alone (GPM)
Piston
Standard Upflow
Continuous
21
Peak (25 psi drop)
26
Cv (flow at 1 psi drop)
5.5
Max. backwash (25 psi drop)
17
Max. Rapid Rinse (25 psi drop)
10
Regeneration
Downflow/Upflow
Upflow only
Adjustable cycles
Yes
Time available
199 minutes per cycle
Meter Information
Meter accuracy
+1/-5% (.25 - 15GPM)
Meter capacity Range (gal).
1 - 60,000
Dimensions
Distributor pilot
1.05”
Drain line
1/2” NPT Quick Connect
Brine line
3/8” Quick Connect
Mounting base
2-1/2” NPSM
Height from top of tank
6.37”
Typical Applications
Water softener
6” - 16” diameter
Filters
6” - 16” diameter
Additional Information
Injector brine system
1610
Electrical rating
24 VAC, 50/60 Hz
Max. VA
15
Estimated shipping weight
11 lbs.
Pressure
Hydrostatic: 300 psi
Working: 20 - 125 psi
Temperature Range
34° - 110° F (1° - 43° C)
Job Specitication Sheet
Valve Specifications
Tank
Diameter
Rein Volume
Injector
Size
BLFC
Size
US (FT
3
)
Metric (Liters)
8
0.75
20
#00
0.125
9
25
#00
0.125
9
1.00
30
#00
0.125
10
1.25
35
#00
0.125
10
1.50
40
#00
0.125
12
45
#00
0.125
12
1.75
50
#00
0.125
12
2.00
55
#0
0.25
13
60
#0
0.25
13
2.25
65
#0
0.25
14
2.50
70
#1
0.25
14
75
#1
0.25
14
2.75
80
#1
0.25
14
3.00
85
#1
0.25
14
3.25
90
#2
0.50
14
95
#2
0.50
14
3.50
100
#2
0.50
16
3.75
105
#3
0.50
16
110
#3
0.50
16
4.00
115
#3
0.50
The chart to the left is for dealer use only. Use this informa-
tion to configure the system to suit the application.
Summary of Contents for 6200 SXT
Page 1: ...6200 SXT Upflow Control Valve for Water Conditioning and Treatment Purposes Service Manual...
Page 21: ...Wiring Diagram 21...
Page 22: ...6200SXT Upflow Brining Rates 22 6200SXT Upflow Brining Rates with Water 20 PSI Regulated Cap...
Page 29: ...29 6200 SXT Valve Dimensional Drawings All dimensions are in Inches mm...
Page 35: ...35...