25
Timer Replacement
5. Remove the three screws from the front bracket. The entire timer assembly will
disconnect from the valve body.
6. Replace the timer with a new one. Attach the three screws to the front bracket
and piston screw to the piston rod. Reinstall the brine valve bracket. Reinstall
brine cam. Close the front cover of the control valve.
7. Reconnect meter cable
Piston screw
Timer Assembly
Self
tapping
screw
Screw
Screw
Screw
Screw
Bracket
Brine
Valve
Brine Cam
Meter Cable
1. Disconnect the meter cable from the
meter.
2. Open the front cover of the control
valve, unscrew the brine cam and
push the brine valve in order to re-
move the cam.
3. Remove the two screws from the
grey brine valve bracket and re-
move it from the valve back plate.
4. Remove the piston screw from the
piston rod.