17
PROBLEM
CAUSE
CORRECTION
20. Err – 109
A. Invalid motor state detected
A. Replace PC board
21. Err – 201
A. Invalid regeneration cycle step detected
A. Replace PC board
22. Err – 204 = Leak
detected
A. Occurs when dP input is active for “ALARM” and the
input is closed. The alarm buzzer will activate and the
screen will display the error.
A. Check for low flow leak. Press NEXT and REGEN
buttons for 3 seconds to resynchronize software
with piston position or disconnect power supply
from PC Board for 5 seconds
and then reconnect to clear error.
23. Err – 400
*
Memory Errors
*(All 400 errors pertain to
memory related errors)
A. Depleted Battery
A. See Operating Display and Maintenance section
B. Defective PC Board
B. Replace PC board
TROUBLESHOOTING GUIDE