Installation
6
Section 3
Installation
3.1 UV System
The UV system is designed to be mounted either horizontally or vertically at the point-of-use or point-of-entry depending on
the specific flow rate of the unit.
If installing the chamber in horizontal position the outlet port must be pointing upwards to ensure all air is fully purged from
the chamber.
Note:
The ideal installation is vertical with the lamp connector on top. This is to prevent water damage from occurring on the
lamp pins and lamp connector.
•
The controller should be mounted either above or beside the chamber. Always mount controller horizontally to prevent
moisture from running down cordage and causing a potential fire hazard. Drip loops in all cordage connected to
controller is highly recommended. Refer to
Figure 6
.
9
IEC replacement power cords for controller
(sold separately)
602636
VH150, VH200, VH410, VH410M, VH200-V, VH410-V, VH410M-V, VP600,
VP600M, VP950, VP950M (N. America)
602637
VH150/2, VH200/2, VH410/2, VH410M/2, VH200-V/2, VH410-V/2, VH410M-V/
2, VP600/2, VP600M/2, VP950/2, VP950M/2 (EU CEE)
260012
VH150-2B, VH200/2B, VH410/2B, VH410M/2B, VH200-V/2B, VH410-V/2B,
VH410M-V/2B, VP600/2B, VP600M/2B, VP950/2B, VP950M/2B (UK)
260013
VH150/2A, VH200/2A, VH410/2A, VH410M/2A, VH200-V/2A, VH410-V/2A,
VH410M-V/2A, VP600/2A, VP600M/2A, VP950/2A, VP950M/2A (Australia, NZ)
260019
NO CONNECTOR, 3-WIRE, BARE LEADS
10
Mounting Brackets/Clamp Assembly
410076
Used on all systems
11
UV Sensor
254NM-C1
VH410M, VH410M-V, VP600M, VP950M
12
Spring
SP008
Used on all systems
13
Retaining nut with the plug
RN-001/1
Used on all systems
C A U T I O N
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle and the lamp connector ground wire connected to the
stainless steel chamber.
Figure 2 Installation - Vertical and Horizontal
Vertical
Horizontal