background image

Manufacturer’s Warranty

21

Section 9

Manufacturer’s Warranty

Our Commitment

VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have 
manufactured your UV system to the highest quality standards and value you as our customer. Should you need any 
support, or have questions about your system, please contact our Technical Support team at 1.800.265.7246 or 

[email protected]

 and we will be happy to assist you. 

How to Make a Warranty Claim

Note: 

To maximise the performance and reliability of your VIQUA product, the system must be properly sized, installed and 
maintained. Guidance on the necessary water quality parameters and maintenance requirements can be found in 
your Owner’s Manual. 

In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your 
dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support 
team at 1.800.265.7246 or e-mail 

[email protected]

. Our fully trained technicians will help you troubleshoot the 

problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of 
the dealer from whom you purchased your VIQUA product (“the source dealer”), as well as a description of the problem 
you are experiencing. To establish proof of purchase when making a warranty claim, you will either need your original 
invoice, or have previously completed and returned your product registration card via mail or online.

Specific Warranty Coverage

Warranty coverage is specific to the VIQUA range of products. Warranty coverage is subject to the conditions and 
limitations outlined under “

General Conditions and Limitations

”.

Ten-Year Limited Warranty for VIQUA UV Chamber

VIQUA warrants the UV chamber on the VIQUA product to be free from defects in material and workmanship for a period of 
ten (10) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective VIQUA 
UV chamber. Please return the defective part to your dealer who will process your claim.

Three-Year Limited Warranty for Electrical and Hardware Components

VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship 
for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any 
defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim.

One-Year Limited Warranty for UV lamps, Sleeves, and UV Sensors

VIQUA warrants UV lamps, sleeves, and UV sensors to be free from defects in material and workmanship for a period of 
one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts 
covered by the warranty.Your dealer will process your claim and advise whether the defective item needs to be returned for 
failure analysis.

Note: 

Use only genuine VIQUA replacement lamps and sleeves in your system. Failure to do so may seriously 

compromise performance and affect warranty coverage.

General Conditions and Limitations

None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor 
scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover 
products that are not installed as outlined in the applicable Owner’s Manual.

Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period 
applicable to the original part.

The above warranties do not include the cost of shipping and handling of returned items.The limited warranties described 
above are the only warranties applicable to the VIQUA range of products. These limited warranties outline the exclusive 
remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort 
(including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, 
implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any 
of these products.

VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the 
above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s 
liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will 
terminate upon expiration of the applicable warranty period.

Summary of Contents for VIQUA VH150

Page 1: ...y f 1 519 763 5069 e mail info viqua com www viqua com Models VH150 VH200 VH410 VP600 VP950 VH410M VP600M VP950M NSF Standard 55 Class B Validated Models VH200 V VH410 V VH410M V Owner s Manual 520110_RevAE System Tested and Certified by NSF International against CSA B483 1 and NSF ANSI 55 for Disinfection Performance Class B ...

Page 2: ...ed VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV equipment An increasing number of calls to VIQUA Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safety risk and is not covered by equipment warranty Unless the...

Page 3: ...it Interrupter GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situation is encountered that is explicitly addressed by the provided maint...

Page 4: ...i E Coli and Fecal Coliform The UV lamp inside the UV system is rated at an effective life of approximately 9000 hours To ensure continuous protection replace the UV lamp annually The UV system is not to be used or played with by children Persons with reduced physical sensory or mental capabilities or lack of experience and knowledge are also not to handle the UV system unless they have been given...

Page 5: ...tion Part Number UV Systems 1 Temperature management valve optional 440179 Optional 2 Flow restrictor Only for certified models 440315 R VH200 V 440316 R VH410 V VH410M V 3 Lamp connector base 270276 R Used on all systems 4 O ring 410867 Used on all systems 5 Open ended GE 214 fused aquartz sleeve with fire polished ends QSO 150 VH150 QS 001 VH200 VH200 V QSO 410 VH410 VH410M VH410 V VH410M V QSO ...

Page 6: ...ement power cords for controller sold separately 602636 VH150 VH200 VH410 VH410M VH200 V VH410 V VH410M V VP600 VP600M VP950 VP950M N America 602637 VH150 2 VH200 2 VH410 2 VH410M 2 VH200 V 2 VH410 V 2 VH410M V 2 VP600 2 VP600M 2 VP950 2 VP950M 2 EU CEE 260012 VH150 2B VH200 2B VH410 2B VH410M 2B VH200 V 2B VH410 V 2B VH410M V 2B VP600 2B VP600M 2B VP950 2B VP950M 2B UK 260013 VH150 2A VH200 2A VH...

Page 7: ...T CONSUME THE WATER tag should be physically installed on the by pass assembly until such time as the system is sanitized and returned to service For more information refer to Section 3 2 If the water is to be consumed while the system is off line the water must be boiled for twenty minutes prior to consumption 2 Select a suitable location for the UV system and its related components As it is reco...

Page 8: ...ndicated on the flow restrictor Refer to Figure 5 Note DO NOT solder connections while attached to the system as this could damage the O ring seals 4 Mount the VIQUA ICE controller horizontally to the wall near the chamber Ideally place the controller above the chamber and away from any water connection point to prevent any water from potentially leaking onto the controller by means of a leak at a...

Page 9: ...r in the cell will become warm as the UV lamp is always on To remedy this run a cold water tap anywhere in the house for a minute to flush out the warm water 3 2 Cleaning Procedure It is imperative that the entire distribution system located after the UV be chemically cleaned to ensure that the plumbing system is free from any contaminants This process must be performed immediately after the UV un...

Page 10: ...his the audible alarm will be silenced The system will display on the controller LED This condition will remain for 12 hours unless the system is manually reset as outlined on page 10 of this manual Section 4 Maintenance 4 1 Replacing UV Lamp Lamp replacement is a quick and simple procedure requiring no special tools The UV lamp must be replaced after 9000 hours of continuous operation approximate...

Page 11: ...ector by squeezing the plastic locking tabs on the side of the connector 4 Hg UV Remove the lamp in upward direction from the chamber and lamp connector base Always hold the lamp at the ceramic ends 5 Hg UV 1 2 Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber 6 4 2 3 1 Attach the connector to the lamp and note that the connector will only ...

Page 12: ... damage due to neglect or misuse 1 Drain the chamber by using the drain port 2 1 2 3 Remove the bottom retaining nut floating spring and O ring 3 1 2 Remove the top retaining nut and O ring 4 Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched...

Page 13: ...ton for 5 seconds which is located on the left side of the controller Each time the timer reset button is pressed the controller alarm is deferred seven days Once the final 7 day deferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller timer refer to Section 4 1 WA RN ING The advanced warning system has been installed to provide the opt...

Page 14: ...cts the discrete 254 nm wavelength of the UV lamp This information is relayed to the VIQUA controller and is the default display shown in UV output The system will display the UV output between 50 to 99 percent When the system drops below 50 a low UV warning is displayed as and alternately flashes at 2 second intervals back to the actual UV level Eg Additionally the system will sound an intermitte...

Page 15: ...entration levels e The UV sensor is not installed correctly 5 2 2 Lamp Life Remaining Days To obtain this reading press the timer reset button a single time and follow the steps as outlined in Section 5 1 3 regarding the operation of this feature 5 2 3 Total Days of Operation To obtain this reading press the timer reset button two times in succession and follow steps as outline in Section 5 1 3 re...

Page 16: ...a remote location via a 4 20 mA signal use an optional Y cable PN 260134 is available from your dealer The Y cable comes with 20 meters 65 of cable for the 4 20 mA signal Procedure Figure 7 Solenoid Installation Optional Solenoid Valve 1 Disconnect the existing sensor cable from the controller 2 1 2 Connect the Y cable to the controller 3 Attach the male end of the removed sensor cable to the fema...

Page 17: ...d re install replace if necessary 410867 Condensation on chamber caused by excessive humidity cold water Check location of UV system and control humidity Inadequate inlet outlet port connections Check thread connections reseal with Teflon tape and re tighten System Shutting Down Intermittently Interrupted controller Ensure system has been installed on its own circuit as other equipment may be draw...

Page 18: ...gpm 68 lpm 4 1 m3 hr 26 gpm 97 lpm 5 8 m3 hr Dimensions Chamber 33 cm x 8 9 cm 13 x 3 5 45 cm x 8 9 cm 15 x 3 5 59 6 cm x 8 9 cm 23 5 x 3 5 78 cm x 8 9 cm 30 7 x 3 5 114 cm x 8 9 cm 45 2 x 3 5 Controller 17 2 cm x 8 1 cm x 6 4 cm 6 8 x 3 2 x 2 5 17 2 cm x 8 1 cm x 6 4 cm 6 8 x 3 2 x 2 5 17 2 cm x 8 1 cm x 6 4 cm 6 8 x 3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 8 x 3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 ...

Page 19: ... HO high output HO high output HO high output HO high output Visual Power On Yes Yes Yes Yes Yes Audible Lamp Failure Yes Yes Yes Yes Yes Lamp Replacement Reminder Yes Yes Yes Yes Yes Visual Lamp Life Remaining Yes Yes Yes Yes Yes Total Running Time Yes Yes Yes Yes Yes Chamber Material 304SS 304 SS 304 SS 304 SS 304 SS 1 Flow rates based on End of Lamp Life 20ºC 2 Units ending in 2B have BSPT conn...

Page 20: ...8 6 kg 19 lbs 13 1 kg 29 lbs Electrical Voltage3 100 240 V 50 60 Hz 100 240 V 50 60 Hz 100 240 V 50 60 Hz Max Current 2 5 A 2 5 A 2 5 A Power Consumption 60 W 78 W 110 W Lamp Watts 46 W 58 W 90 W Maximum Operating Pressure 125 psi 861 kPa 125 psi 861 kPa 125 psi 861 kPa Minimum Operating Pressure 15 psi 103 kPa 15 psi 103 kPa 15 psi 103 kPa Ambient Water Temperature 2 40 ºC 36 104 ºF 2 40 ºC 36 10...

Page 21: ...dware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year Limited Warranty for UV lamps Sleeves and UV Sensors VIQUA warrants UV lamps sleeves a...

Page 22: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com ...

Reviews: