Safety Information

3

Section 1

Safety Information

These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all 
danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to 
the equipment.

Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any 
manner other than that specified in the installation manual.

1.1 Potential Hazards:

Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.

1.2 Safety Precautions:

Waste electrical and electronic equipment (WEEE). This symbol 
indicates that you should not discard wasted electrical or electronic 
equipment (WEEE) in the trash. For proper disposal, contact your local 
recycling/reuse or hazardous waste center.

This symbol indicates not to store any combustible or flammable 
material close to the system.

This symbol indicates there is Mercury present.

This symbol indicates that the contents of the transport package are 
fragile and the package should be handled with care.

This is the safety alert symbol. Obey all safety messages that follow 
this symbol to avoid potential injury. When on the equipment, refer to 
the Operational and Maintenance manual for additional safety 
information.

This symbol indicates safety glasses with side protection is required for 
protection against UV exposure.

This symbol indicates a risk of electrical shock and/or electrocution 
exists.

This symbol indicates gloves must be worn.

This symbol indicates the marked equipment may contain a 
component that can eject forcibly. Obey all procedures to safely 
depressurize.

This symbol indicates safety boots must be worn.

This symbol indicates the system is under pressure.

This symbol indicates the operator must read all available 
documentation to perform required procedures.

This symbol indicates there is a potential UV hazard. Proper protection 
must be worn.

This symbol indicates the plumber must use copper piping.

This symbol indicates the marked item could be hot and should not be 
touched without care.

This symbol indicates that the system should only be connected to a 
properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI).

This symbol indicates there is a potential for VERY hot water when 
flow is started.

D A N G E R

Failure to follow these instructions will result in serious injury or death.

  •

Electric Shock:

 To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a 

situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, 
refer to an authorized service facility.

  •

GROUNDING: 

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric 

current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. 
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. 
Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service 
personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fit in 
the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system.

  •

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

: To comply with the National Electrical Code (NFPA 70) and to provide additional 

protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 
30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.

  •

DO NOT operate the UV system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner.

  •

DO NOT use this UV system for other than intended use (potable water applications). The use of attachments not recommended or sold by the 
manufacturer / distributor may cause an unsafe condition.

  •

DO NOT install this UV system where it will be exposed to the weather or to temperatures below freezing.

  •

DO NOT store this UV system where it will be exposed to the weather.

  •

DO NOT store this UV system where it will be exposed to temperatures below freezing unless all water has been drained from it and the water 
supply has been disconnected.

Hg

UV

Cu

Summary of Contents for VIQUA VH150

Page 1: ...y f 1 519 763 5069 e mail info viqua com www viqua com Models VH150 VH200 VH410 VP600 VP950 VH410M VP600M VP950M NSF Standard 55 Class B Validated Models VH200 V VH410 V VH410M V Owner s Manual 520110_RevAE System Tested and Certified by NSF International against CSA B483 1 and NSF ANSI 55 for Disinfection Performance Class B ...

Page 2: ...ed VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV equipment An increasing number of calls to VIQUA Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safety risk and is not covered by equipment warranty Unless the...

Page 3: ...it Interrupter GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situation is encountered that is explicitly addressed by the provided maint...

Page 4: ...i E Coli and Fecal Coliform The UV lamp inside the UV system is rated at an effective life of approximately 9000 hours To ensure continuous protection replace the UV lamp annually The UV system is not to be used or played with by children Persons with reduced physical sensory or mental capabilities or lack of experience and knowledge are also not to handle the UV system unless they have been given...

Page 5: ...tion Part Number UV Systems 1 Temperature management valve optional 440179 Optional 2 Flow restrictor Only for certified models 440315 R VH200 V 440316 R VH410 V VH410M V 3 Lamp connector base 270276 R Used on all systems 4 O ring 410867 Used on all systems 5 Open ended GE 214 fused aquartz sleeve with fire polished ends QSO 150 VH150 QS 001 VH200 VH200 V QSO 410 VH410 VH410M VH410 V VH410M V QSO ...

Page 6: ...ement power cords for controller sold separately 602636 VH150 VH200 VH410 VH410M VH200 V VH410 V VH410M V VP600 VP600M VP950 VP950M N America 602637 VH150 2 VH200 2 VH410 2 VH410M 2 VH200 V 2 VH410 V 2 VH410M V 2 VP600 2 VP600M 2 VP950 2 VP950M 2 EU CEE 260012 VH150 2B VH200 2B VH410 2B VH410M 2B VH200 V 2B VH410 V 2B VH410M V 2B VP600 2B VP600M 2B VP950 2B VP950M 2B UK 260013 VH150 2A VH200 2A VH...

Page 7: ...T CONSUME THE WATER tag should be physically installed on the by pass assembly until such time as the system is sanitized and returned to service For more information refer to Section 3 2 If the water is to be consumed while the system is off line the water must be boiled for twenty minutes prior to consumption 2 Select a suitable location for the UV system and its related components As it is reco...

Page 8: ...ndicated on the flow restrictor Refer to Figure 5 Note DO NOT solder connections while attached to the system as this could damage the O ring seals 4 Mount the VIQUA ICE controller horizontally to the wall near the chamber Ideally place the controller above the chamber and away from any water connection point to prevent any water from potentially leaking onto the controller by means of a leak at a...

Page 9: ...r in the cell will become warm as the UV lamp is always on To remedy this run a cold water tap anywhere in the house for a minute to flush out the warm water 3 2 Cleaning Procedure It is imperative that the entire distribution system located after the UV be chemically cleaned to ensure that the plumbing system is free from any contaminants This process must be performed immediately after the UV un...

Page 10: ...his the audible alarm will be silenced The system will display on the controller LED This condition will remain for 12 hours unless the system is manually reset as outlined on page 10 of this manual Section 4 Maintenance 4 1 Replacing UV Lamp Lamp replacement is a quick and simple procedure requiring no special tools The UV lamp must be replaced after 9000 hours of continuous operation approximate...

Page 11: ...ector by squeezing the plastic locking tabs on the side of the connector 4 Hg UV Remove the lamp in upward direction from the chamber and lamp connector base Always hold the lamp at the ceramic ends 5 Hg UV 1 2 Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber 6 4 2 3 1 Attach the connector to the lamp and note that the connector will only ...

Page 12: ... damage due to neglect or misuse 1 Drain the chamber by using the drain port 2 1 2 3 Remove the bottom retaining nut floating spring and O ring 3 1 2 Remove the top retaining nut and O ring 4 Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched...

Page 13: ...ton for 5 seconds which is located on the left side of the controller Each time the timer reset button is pressed the controller alarm is deferred seven days Once the final 7 day deferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller timer refer to Section 4 1 WA RN ING The advanced warning system has been installed to provide the opt...

Page 14: ...cts the discrete 254 nm wavelength of the UV lamp This information is relayed to the VIQUA controller and is the default display shown in UV output The system will display the UV output between 50 to 99 percent When the system drops below 50 a low UV warning is displayed as and alternately flashes at 2 second intervals back to the actual UV level Eg Additionally the system will sound an intermitte...

Page 15: ...entration levels e The UV sensor is not installed correctly 5 2 2 Lamp Life Remaining Days To obtain this reading press the timer reset button a single time and follow the steps as outlined in Section 5 1 3 regarding the operation of this feature 5 2 3 Total Days of Operation To obtain this reading press the timer reset button two times in succession and follow steps as outline in Section 5 1 3 re...

Page 16: ...a remote location via a 4 20 mA signal use an optional Y cable PN 260134 is available from your dealer The Y cable comes with 20 meters 65 of cable for the 4 20 mA signal Procedure Figure 7 Solenoid Installation Optional Solenoid Valve 1 Disconnect the existing sensor cable from the controller 2 1 2 Connect the Y cable to the controller 3 Attach the male end of the removed sensor cable to the fema...

Page 17: ...d re install replace if necessary 410867 Condensation on chamber caused by excessive humidity cold water Check location of UV system and control humidity Inadequate inlet outlet port connections Check thread connections reseal with Teflon tape and re tighten System Shutting Down Intermittently Interrupted controller Ensure system has been installed on its own circuit as other equipment may be draw...

Page 18: ...gpm 68 lpm 4 1 m3 hr 26 gpm 97 lpm 5 8 m3 hr Dimensions Chamber 33 cm x 8 9 cm 13 x 3 5 45 cm x 8 9 cm 15 x 3 5 59 6 cm x 8 9 cm 23 5 x 3 5 78 cm x 8 9 cm 30 7 x 3 5 114 cm x 8 9 cm 45 2 x 3 5 Controller 17 2 cm x 8 1 cm x 6 4 cm 6 8 x 3 2 x 2 5 17 2 cm x 8 1 cm x 6 4 cm 6 8 x 3 2 x 2 5 17 2 cm x 8 1 cm x 6 4 cm 6 8 x 3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 8 x 3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 ...

Page 19: ... HO high output HO high output HO high output HO high output Visual Power On Yes Yes Yes Yes Yes Audible Lamp Failure Yes Yes Yes Yes Yes Lamp Replacement Reminder Yes Yes Yes Yes Yes Visual Lamp Life Remaining Yes Yes Yes Yes Yes Total Running Time Yes Yes Yes Yes Yes Chamber Material 304SS 304 SS 304 SS 304 SS 304 SS 1 Flow rates based on End of Lamp Life 20ºC 2 Units ending in 2B have BSPT conn...

Page 20: ...8 6 kg 19 lbs 13 1 kg 29 lbs Electrical Voltage3 100 240 V 50 60 Hz 100 240 V 50 60 Hz 100 240 V 50 60 Hz Max Current 2 5 A 2 5 A 2 5 A Power Consumption 60 W 78 W 110 W Lamp Watts 46 W 58 W 90 W Maximum Operating Pressure 125 psi 861 kPa 125 psi 861 kPa 125 psi 861 kPa Minimum Operating Pressure 15 psi 103 kPa 15 psi 103 kPa 15 psi 103 kPa Ambient Water Temperature 2 40 ºC 36 104 ºF 2 40 ºC 36 10...

Page 21: ...dware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year Limited Warranty for UV lamps Sleeves and UV Sensors VIQUA warrants UV lamps sleeves a...

Page 22: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com ...

Reviews: