Operation
13
Procedure:.
Section 5
Operation
5.1 Basic Systems Incorporating BA-ICE-C and BA-ICE-CL Controllers
5.1.1 Lamp Life Remaining (days)
The controller tracks the number of days of operation of the lamp and the controller. The default screen will display
the total lamp life remaining (in days). The controller will count down the number of days remaining until the lamp requires
changing (365 days to 1 day). At “0” days, the controller will display
and sound an intermittent audible chirp
(1 second on, 5 seconds off), indicating the need to change the lamp.
5.1.2 Understanding your “A3” Code
DEFERRAL
- Once the “A3” or end of lamp life message is shown on the LED display, the audible alarm can be
deferred up to 4 separate times. The delay is designed to allow you time to address the alarm while you obtain a new UV
lamp. This can be done by simply depressing the timer reset button for 5 seconds, which is located on the left side of the
controller. Each time the timer reset button is pressed the controller alarm is deferred seven days. Once the final 7 day
deferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller
timer, refer to
Section 4.1
.
WA R N I N G
The advanced warning system has been installed to provide the optimum protection against microbiological contamination in water.
DO NOT
disregard
the warning signals. The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on
a regular basis.
1
•
Disconnect the UV sensor from
the controller by disconnecting the
sensor cable.
2
•
Remove the UV sensor by grasping
the body of the sensor and rotating
it counter-clockwise.
3
0
30
15
45
30 mins
Commercial
Scale
Remover
•
Submerge only the end of the
sensor in the commercial scale
remover for 30 minutes.
4
1
2
•
Clean the sensor with a cotton
swab and spray with water.
•
Re-insert the UV sensor until a
water-tight seal is achieved.