Maintenance
11
Procedure:
4.2 Cleaning and Replacing Quartz Sleeve
Note:
Minerals in the water slowly form a coating on the lamp sleeve. This coating must be removed because it reduces the
amount of UV light reaching the water, thereby reducing performance. If the sleeve can not be cleaned, it must be replaced.
Prerequisites:
•
Shut off water supply and drain all lines.
•
Remove the UV lamp. Refer to
Section 4.1
.
1
•
Shut off the water line to
chamber and release system
pressure before servicing.
2
0
30
15
45
10 mins
•
Disconnect main power
source and allow the unit to
cool for 10 minutes.
3
1
2
•
Remove the lamp connector
by squeezing the plastic
locking tabs on the side of the
connector.
4
Hg
UV
•
Remove the lamp in upward
direction from the chamber
and lamp connector base.
•
Always hold the lamp at the
ceramic ends.
5
Hg
UV
1
2
•
Insert the new lamp fully into
the chamber leaving about
two inches of the lamp
protruding from the chamber.
6
4
2
3
1
•
Attach the connector to the
lamp and note that the
connector will only allow
correct installation in one
position.
7
1
2
click
•
Push the lamp connector
against lamp connector base
together until an audible click
is heard.
•
Re-pressurize the system to
check for leaks.
8
•
Hold down the timer reset
button and reapply power to
the controller until you see
, then release timer
reset button.
•
A 5 second delay will occur
until you hear an audible tone
and LED display will read
once again
.