![Water quality VIQUA VH150 Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/water-quality/viqua-vh150/viqua-vh150_owners-manual_3571081005.webp)
General Information
5
* Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned
periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess
of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of
your UV system. These water quality parameters can be tested by your local dealer, or by most private analytical
laboratories.
Proper pre-treatment is essential for the UV system to operate as intended
.
Section 2
General Information
Figure 1 System Components
Item
Description
Part Number
UV Systems
1
Temperature management valve (optional)
440179
Optional
2
Flow restrictor (Only for certified models)
440315-R
VH200-V
440316-R
VH410-V, VH410M-V
3
Lamp connector base
270276-R
Used on all systems
4
O-ring
410867
Used on all systems
5
Open-ended, GE 214 fused aquartz sleeve
with fire polished ends
QSO-150
VH150
QS-001
VH200, VH200-V
QSO-410
VH410, VH410M, VH410-V, VH410M-V
QSO-600
VP600, VP600M
QSO-950
VP950, VP950M
6
Hard glass, coated HO UV lamps for long,
consistent life (9000 hours)
S150RL-HO VH150
S200RL-HO
VH200, VH200-V
S410RL-HO
VH410, VH410M, VH410-V, VH410M-V
S600RL-HO
VP600, VP600M
S950RL-HO
VP950, VP950M
7
Retaining Nut
RN-001
Used on all systems
8
Controller (for 100-240V/50-60Hz models
only)
BA-ICE-CL
VH150, VH200, VH410, VH200-V, VH410-V
BA-ICE-C
VP600, VP950
BA-ICE-CM
VH410M, VH410M-V, VP600M, VP950M
2
8
9
10
11
12
13
1
3
4
5
6
7