15
3.2.
WHITE BALANCE
3.2.1.
WHITE BALANCE MODE (MODE)
Set the WHITE BALANCE control mode.
Default: ATW
Table 8. WHITE BALANCE - MODE
Menu
Item
Value
Description
MODE
ATW
Automatically follow WHITE BALANCE (Approx. 2000K-15000K)
by matching the color temperature of a subject.
The range of color can follow is wider than the
INDOOR/OUTDOOR.
ONE
PUSH
Fix WHITE BALANCE at the specific color temperature.
Combined use the WHITE BALANCE convergence movement
(PUSH).
Utilize the WHITE BALANCE convergence movement (PUSH) to
complete while imaging such as a white paper.
INDOOR
WHITE BALANCE automatically follows (Approx. 4600K-7200K).
Set as easy to follow indoor light source (fluorescent light, etc.).
OUTDOOR
WHITE BALANCE automatically follows (Approx. 4600K-10000K).
Set as easy to follow outdoor light source (sunlight, etc.).
MANUAL
Manually set WHITE BALANCE
3.2.2.
One Push Trigger (PUSH)
Complete the WHITE BALANCE convergence movement while the WHITE BALANCE
mode is
ONE PUSH. The B and R gain value after completing PUSH operation retains even
when the power of the camera was turned off, or the WHITE BALANCE mode was changed.
When the “3.7. FACTORY RESET” is completed, the B and R gain value after completing
PUSH operation will return to default settings.
3.2.3.
B-Gain (BLUE)
Set the B and R gain value while the WHITE BALANCE mode is “MANUAL”.
Lager the B gain, it will be bluer. The setting value range is 0-100.
Default: 50