![Wascomat Selecta S28/125 Operating & Maintenance Manual Download Page 74](http://html1.mh-extra.com/html/wascomat/selecta-s28-125/selecta-s28-125_operating-and-maintenance-manual_3493763074.webp)
Machine displays
error code 09E
Is the
microswitch
working correctly?
Note!
Yes
No
Change microswitch
Can the
microswitch
close?
Yes
No
Check that machine
suspension is
undamaged
Can the
microswitch
close, measured
at edge
connector?
Yes
No
Change PCB
Change wiring
Is the
sensing pin
on the micro-
switch positioned
correctly?
No
Yes
Rectify
The imbalance switch indicates imbalance
(closed microswitch) on changeover from wash
stage to drain stage. In the service program,
closed microswitch is indicated by program
indicator arrow 4 being lit.
Fault-finding
19
Note!
Machine door
must be closed
when service
program in use
95.08