Installation
14
12
13
1832
1870
1844
Water connection
NOTE
All plumbing must conform to national
and local plumbing codes.
Incoming water lines do not require non-return or
back-suction valves, as the machine is already
fitted with a siphon breaker. However, all inco-
ming lines must be fitted with shut-off valves.
•
Water inlets are labelled for hot and cold
water connection.
•
Before connecting the water hoses flush the
water system thoroughly and check that the
filter at the machine inlet is fitted correctly.
This is essential since dirt and grit in the water
lines may clog the inlet valve filter screens
and/or the drain pilot valve. This could cause
the machine to fill very slowly or the drain
valve not operate properly.
•
Connect the machine to the water mains with
3/4" reinforced rubber hosing not to exceed 6
ft in length. Hang the hosing in a large loop.
Do not use rigid piping.
Never force a hose onto the threads or you may
cause cross-threading and leaks. If this occurs,
place the threaded portion of the hose over the
valve threads and push forward firmly, to catch
the next thread. Then tighten.
Fig.
12
Fig.
14
Fig.
13
8
S28/125
S28/185
1846
S28/125
S28/185
hot water cold water
hot water cold water hot water
(to detergent supply box)