36
1833
61
1207
62
Maintenance
Preventive maintenance has been reduced to a
minimum by the careful design of reliable
components and material.
However, the following measures should be taken
at regular intervals and in proportion to the hours
of service.
IMPORTANT!
Make certain that all electrical power to the
machine is shut off before removing top or
rear panels.
Daily
•
Check the door lock and interlock before
starting operations.
•
The soap supply box should be cleaned at the
end of each working day as follows:
– Use a spatula to scrape loose any detergent
which may have stuck on the inside of the
dispenser.
– Flush the loosened detergent with warm
water.
– Wipe dry and leave lid open.
•
Check that the drain valve does not leak and
that it opens properly.
•
Check that the door does not leak. Clean
residual detergent and foreign matter from the
door gasket.
•
Wipe the outside of the machine.
•
When the machine is not in use, leave door
slightly open to allow moisture to evaporate.
Weekly
•
Remove the hose from the drain connection
and clean the inside of the drain valve.
Every three months
•
Remove the rear panel of the machine and
check that the V-belt of the wash motor is
undamaged and correctly tensioned.
•
Check that all tubing, piping and connections
are free from leaks.
•
Wipe and clean the inside of the machine,
making sure that the control components are
protected from moisture and dirt during the...
Fig.
61
Fig.
62
Maintenance
Summary of Contents for Selecta S28/125
Page 2: ......
Page 6: ......
Page 35: ...28 Mechanical and electrical design 1791 46 S28 185 208 240 V 60 Hz single phase...
Page 55: ...Fault finding Circuit Board...