![Wascomat Selecta S28/125 Operating & Maintenance Manual Download Page 61](http://html1.mh-extra.com/html/wascomat/selecta-s28-125/selecta-s28-125_operating-and-maintenance-manual_3493763061.webp)
Machine will not start when
start button is activated
Does PCB
start up, but
nothing more
happens?
Yes
No
Connect panel plate
correctly
No
Is connector
clean?
Yes
No
Cange PCB
Clean it
Fault-finding
6
Close door
Is the door
closed?
Yes
No
Are micro-
switch and wiring
for "door closed"
OK?
Yes
No
Rectify microswitch
or wiring
Is edge
connector
on PCB OK?
Yes
No
Rectify edge
connector
Is panel plate
correctly
connected?
Yes
Continue on
page 7
95.08
Summary of Contents for Selecta S28/125
Page 2: ......
Page 6: ......
Page 35: ...28 Mechanical and electrical design 1791 46 S28 185 208 240 V 60 Hz single phase...
Page 55: ...Fault finding Circuit Board...