76
Open door. Close door and try to restart the
machine.
Error code returns
No error code
Set program control unit to service mode (see
”To switch on service mode”). The door status
switch will now be indicated by the LED
(illustrated).
Press in the door status switch manually and
check if this is indicated by the LED.
LED does not light.
LED lights.
Disconnect the two wires from the switch. Short-
circuit the two wires.
LED does not light.
LED lights.
Remove connector X71 from the program control
unit PCB. Short-circuit between inputs 3 and 4.
LED does not light.
LED lights.
Trouble shooting
1
4
X71
2316
02E
Door status switch open
during program operation.
Check whether the pin on the
door or the plastic slide which
the pin presses against are
worn. Replace any worn
parts.
Continuity fault in wiring or
connectors. Check wiring and
replace if necessary.
Fault in program control unit
PCB. Replace PCB.
Short-
circuit
Door lock switch faulty.
Replace switch.
Cause/Action
Fault-finding
Error code/symptoms
Transient fault in door lock or
program PCB.
3430
LED
indicating
Door
status
switch