48
Mechanical and electrical design
Fig.
56
1
2
3
4
5
6
7
8
9
10
11
approx. 5 seconds
4710
LED pattern of flashes
Error code/message
on display
Cause
31E
Heat sink on MCU too hot.
32E
Motor thermal protection device activated
33E
MCU has received start command,
but not received interlock signal.
13E
Communication error MCU – PCU
-
Short in motor windings, wiring or internally in MCU.
MCU will restart automatically.
35E
Once again short in motor windings, wiring or internally
in MCU.
36E
Fault in interlock circuits in MCU.
37E
MCU DC voltage too low.
38E
MCU DC voltage too high
39E
Ripple DC-bus (EWD 4000 only).
41E
Fault/error in MCU overheating circuits.
56
Error indication patterns
If a fault or error occurs in the motor or motor control unit, the MCU sends
an error signal to the PCU board. In addition to an error code showing on
the display, errors/faults are revealed by the flashing of a yellow LED on the
MCU board. The table below shows how to identify the error/fault on the
basis of the flashing pattern of this LED.
Fig.
57