72
Service program
Error Code
Cause
37
LED test
41-42
Coin mechanism (see Page 39, Program control
unit).
43-44
Counter (hours) for accumulated operating time (see
Page 39, Program control unit).
45
Last error code flagged.
51-54
Program EPROM part number (see Page 39,
Program control unit).
91
Coin value, coin slot 1. This is set using the price-
programming switch (see Page 39, Program
control unit).
92
Coin value, coin slot 2. This is set using the price-
programming switch (see Page 39, Program
control unit).
93
Availability of pause function in coin-operated
machines. Can be 1 = Yes or 0 = No. This is set
using the priceprogramming switch (see Page 39,
Program control unit).
94
Availability of rapid advance function in coin-
operated machines. Can be 1 = Yes or 0 = No. This
is set using the price-programming switch (see
Page 39, Program control unit).
95
Activate coin-op input. Can be 1 = Active or 0 = Off.
This is set using the price-programming switch (see
Page 39, Program control unit).
97
To program a price reduction on a coin-operated
machine, use the price-programming button. You set
a price reduction as a percentage between 0 and
99. Rounding-up will take place to the next coin
value upwards. A price reduction of 99% means a
free wash program.