CHECKING STATUS OF BATTERIES AND CHARGING CURRENT 

1. Press any key to wake up the remote, if the LCD display has powered off. 

2. Press 

 MODE

3. Press

  ZONE

as necessary to choose the appropriate zone (

1

 thru 

9

).  

4. Press

  ENTER

to save your selection. 

5.

MAX-OPEN

 will be displayed and flashing.  

6. Press

▲ ▼

 until  

ST

  is displayed and flashing.  

7. Press

  ENTER

8. Press

▲ ▼

 to choose the ID number (

1

 thru 

9

) of the operator within the zone.  

9. Press

  ENTER

to save your selection.  

10. Press 

▲ ▼

 to cycle viewing either the solar charging rate in mA, operator battery status, 

or  the remote battery.  

Solar  charging  rate  is  measured  in  Milliampere  (mA).  Refer  below  for  more 
information on charging rate. 

11. Press

  MODE

to return to main screen. 

Charging Rate 

mA is the abbreviation for Milliampere, which is a unit of electrical current flow. In this 
case, it is the  measurement of current into the battery  when charging, and it  will range 
between 0 and 150 mA.  

The charging measurement is taken each time the status is requested and is a 'snap shot' of 
the conditions at that particular moment in time.  

This measurement is highly variable and depends directly upon the level of sunlight on the 
solar panel. Be aware of external influences which affect the light level, these are: direction 
and angle of exposure of the solar panel to the light source, sky conditions, clouds, man -
made  structures  or  trees  which  cause  shadows  on  all  or  part  of  the  solar  panel,  and 
maintenance of the solar panel itself, to keep it clean. 

Current  flow  is  also  highly  dependent  upon  the  battery  state  of  charge  and  the  status 
measurement may report zero or low mA, even when solar and all other conditions are 
optimum. For example, the solar panel could be outputting 40 mA on a battery that has a 
low charge, however on a battery with near full charge the output may only be 10 mA. 

Solar Smart limits the maximum charge current for safety reasons, to extend battery life, 
and to prevent over-charging damage to the battery. 

Battery Alerts 

The  

  icon will be displayed on the remote when the remote batteries are in need of 

replacement. 

The  

   icon  will be displayed when the operator battery is low. When the operator 

battery is critically low, the operator will be allowed to close; however will not be able to 
open until the battery is recharged to a sufficient level. 

Remote Battery Status 

Solar Charging Rate 

Operator Battery Status

Summary of Contents for Solar Smart GSVMS

Page 1: ...ANUAL 800 388 0293 Fax 207 216 4562 csm wascoproducts com www wascoskylights com Eastern Facility 85 Spencer Drive Unit A Wells ME 04090 Western Facility 6645 Echo Avenue Reno NV 89506 with Rain Senso...

Page 2: ...hment link on chain is fastened to the sash by a release pin 7 AC trickle charger included 8 Adaptable to awning and hopper windows and skylights Remote Highlights 1 Large and readable display with bi...

Page 3: ...d bracket g bracket ket tabs UIRED ing the operator ing the chain clip ing the solar panel and bracket DO NOT INSTALL THE BATTERIES UNTIL DIRECTED TO DO SO Chain Clip Battery Cover Operator Battery AC...

Page 4: ...up the remote if the LCD display has powered off 2 Press ZONE to choose a single zone 1 thru 9 of operators or ALL to operate all operators in all zones 3 Press OPEN or CLOSE to open or close the win...

Page 5: ...Manual sion 8 12 2015 ON of the SOLAR PANEL and RAIN SENSOR panel must be mounted with airspace for cooling and performance efficiency as intain the product life span e solar panel face down on a fla...

Page 6: ...ion 7 ZONE ALL and the temperature should now be displayed Installation and User Manual 7 Revision 8 12 2015 INITIAL REMOTE SETUP and CONFIGURATION The following are applicable for configuring the mai...

Page 7: ...The remote will need to be paired within 2 minutes or the operator will default back to the previous settings 1 Remove the battery cover from the operator If connected disconnect the battery connecto...

Page 8: ...operator zones ID numbers and or adding additional operators can only be performed using the main remote The changed settings would then need to be re sent from the main to the secondary remote s Ens...

Page 9: ...from the main remote It will wait for 30 seconds 2 MAIN REMOTE STEPS a Press and hold MODE release when PAIR SET is displayed b Press MODE twice to move past RE ZONE to display M in the upper right c...

Page 10: ...ON or OFF for one second then SUCC for 2 seconds indicating success Press MODE a few times to return to the home screen a If setting not successful LCD displays FAIL for 1 second then returns to the...

Page 11: ...unction off 9 Press ENTER 10 ST is now displayed and flashing Press MODE to return to the home screen OR press to scroll and set other features 11 The Time To Close selection will be retained in memor...

Page 12: ...e operator s is open The factory setting MAX OPEN limit is set to open up to 80 of full open position 1 Press any key to wake up the remote if the LCD display has powered off 2 Press MODE 3 Press ZONE...

Page 13: ...Press ENTER 8 Press to set the desired temperature or NULL to turn function off for this zone 9 Press ENTER to save your selection The temperature in which the operator will run has now been set Next...

Page 14: ...lar moment in time This measurement is highly variable and depends directly upon the level of sunlight on the solar panel Be aware of external influences which affect the light level these are directi...

Page 15: ...hen PAIR SET is displayed 3 Press MODE again to display RE ZONE 4 Press ZONE as necessary to choose the appropriate zone 1 thru 9 of the operator to be moved to another zone 5 Press ENTER to save your...

Page 16: ...se set MAX OPEN 4 Temperature change must be maintained for 10 minutes before the temperature control TC function will operate For more Trouble Shooting Tips please visit www SolarSmartOpener com ADVA...

Page 17: ...se record your Remote settings for ease of reference as well as assist in troubleshooting ZONE ID Location 1 1 2 3 4 5 6 7 8 9 2 1 2 3 4 5 6 7 8 9 3 1 2 3 4 5 6 7 8 9 4 1 2 3 4 5 6 7 8 9 5 1 2 3 4 5 6...

Reviews: