background image

6

User guide for IP Weather Station WARIO ME13

1

Important notes

It is important to read this user guide very carefully and follow all the instructions given 
while installing the device. Then store it for future reference if necessary.

Device specification

The ME13 weather station 

consists of a control unit and a set of outdoor sensors. It can 

be further extended with additional sensors and devices, with the possibility of controlling 
the device based on integrated weather conditions. The measured values can easily be 
displayed on a computer, smartphone, tablet or any other device with an Internet browser. 
The weather station can also be integrated into higher-level systems. Communication is 
then mediated via TCP/IP protocol and data can be read using the ModBus technology or 
the XML format. More information about integration of the weather station into higher-
level systems can be found in a separate user guide available at 

www.meteo-pocasi.cz

 in the 

Download

” section. 

If you want to access your data in a clear and easily understandable way or if you want to 
share it with other users, you can register your weather station at 

www.meteo-pocasi.cz

 and 

you will get many additional features and extensions.

Safety instructions

Please read the following instructions very carefully before plugging in your device to 
electricity or connecting it to your computer, in order to prevent any potential injuries and 
minimize the risk of damaging the weather station and/or its accessories.

The manufacturer carries no responsibility for any damage resulting from incorrect installation 
or non-compliance with this user guide or technical instructions. If these safety instructions 
are not followed the device may not be safe to use and data might be inaccurate. Wanet Ltd. 
offers warranty service conditions of which are specified in a document available at www.
meteo-pocasi.cz and warranty is performed based on this document or the legislation of 
the Czech Republic. Installation and configuration of the weather station and computer 
network should be performed by a person with the appropriate knowledge and skills.

Opening or removing the outer lid can result in electrical shock. Because the device is 
exposed to outdoor weather conditions, all the installation steps must be followed carefully 
to prevent water leaking into the control unit area. The supplied power supply can only 
be used in electrical circuit with a voltage that corresponds to the label on the power 
supply. Some parts of the sensors are fragile and therefore close attention must be paid 
while handling them during installation or cleaning. Do not use the device in environments 
with aggressive chemical compounds and gases and do not clean or soak the device 
with chemical detergents. Do not place the weather station close to devices with strong 
electromagnetic fields. 

Do not use the device if it is malfunctioning or if it shows visible signs of damage. The 
outdoor sensors for measuring wind speed and direction, solar radiation and precipitation, 
should be kept clean during winter. Also keep in mind that even a thin layer of snow can 
significantly influence the measured values, especially in case of the rain gauge if not heated 
(heated rain gauge is optional).

2

Locating the Weather Station

Installing and using the weather station

The weather station is intended for outdoor use. Minimum distance from the ground is 1 m 
and the maximum possible distance from the energy supply, data switch or router is 25 m. 
The station must be placed in an open-space and the surrounding area must be free of any 
devices that could potentially influence the measured values. In order to guarantee accurate 
measurements, the station must also be unshaded and no obstacles should prevent normal 
air flow. In the winter, the mechanical sensors must be kept clean.

Summary of Contents for ME13

Page 1: ...User guide for IP Weather Station WARIO ME13 for firmware ME220005...

Page 2: ...s strana 11 Status LED diode strana 11 Reset and default button strana 11 Function Restart by pressing button strana 11 Function Default configuration by pressing button strana 11 5 Sensor range and r...

Page 3: ...heated rain gauge strana 16 Tab Device strana 16 Search devices strana 16 List of connected devices strana 16 14 Section Location strana 16 Location strana 16 Elevation strana 16 Geographical coordin...

Page 4: ...upport strana 20 Status LED diode setting strana 20 Information strana 20 21 Viewing measurements section Meteo strana 20 22 Description of the individual tabs in the Meteo section strana 21 23 Viewin...

Page 5: ...na 25 32 Section events Action condition met not met strana 25 Action Output setting strana 25 Set output to strana 25 Action Output timing strana 25 Select output strana 25 State strana 25 Maintain a...

Page 6: ...h are specified in a document available at www meteo pocasi cz and warranty is performed based on this document or the legislation of the Czech Republic Installation and configuration of the weather s...

Page 7: ...that are not used must be covered with rubber plugs which are also supplied with the station The weather station is equipped with locking connectors RJ11 and RJ45 for connecting the sensors and the da...

Page 8: ...9 9 9 Step 3 1 1 1 1 1 2 2 2 3 4 6 5 2 7 8 3 4 6 5 2 8 7 10 11 3 2 3 4 2 3 2 W 3 2 4 3 4 6 5 2 5 9 6 Connector for connecting rain gauge Signal LED diode Reset button Resets weather station to factory...

Page 9: ...nect the optional temperature or temperature humidity sensors to the receptacles labeled S1 or S2 z z Connect the relay outputs to receptacles OUT1 or OUT2 z z Connect the WBUS interface data cable to...

Page 10: ...r max 25 m LAN IPWeather Station WARIO ME13 WAN Internet 230V 12 Rain gauge 7 Wind speed and wind direction sensor POE adapter data cable Optional temperature and humidity sensors WBUS interface data...

Page 11: ...2 5 s then the green LED diode for 2 5 s and finally the red LED diode again for 2 5 s you can release the button and the z z solar radiation z z rain gauge optionally with automatic heating mechanis...

Page 12: ...aximum current of 0 25 A and voltage of 30 V Operating temperature of Weather station 30 to 65 C S1 and S2 connectors for independent cable temperature or temperature humidity sensors Range Resolution...

Page 13: ...e entire weather station Make sure all the parameters are properly set in order to ensure correct measurement and access to the actual station If you are accessing the Settings station for the very fi...

Page 14: ...ress configuration Proxy port Proxy server port configuration 10 Section Users This section is for specifying login details for access to the weather station If you forget the login information it wil...

Page 15: ...nality of the network device IP addresses of up to 8 sensors can be specified Label Option to name a particular sensor IP address Option to specify the IP address of a network device Tab measurement s...

Page 16: ...ThislistshowsalldevicescurrentlyconnectedtotheWBUS withthepossibilityofconfiguring or removing them 14 Section Location This section is to specify the location of the weather station in order to corre...

Page 17: ...for the Overview tab Reset to default view This option will restore the default view for the Overview tab 16 Section Email This section is for specifying information regarding email communication If y...

Page 18: ...here you want to send data Server can be specified either by its domain name or an IP address Port Configuration of the port number used for communication with the server in most cases set to 80 Addre...

Page 19: ...n about the station Serial Number Weather station serial number Model Weather station model Firmware Current firmware version installed in the station If the station is connected to the Internet a war...

Page 20: ...l information about the weather station 21 Viewing measurements section Meteo A B C G H I J K L 3 F D E A Weather station menu B Measured values sensors tab on the main dashboard C trend graph for the...

Page 21: ...w you previous value depending on the currently displayed value and time span H The Day button shows information for the current day and clicking the arrow next to it allows choosing any other day in...

Page 22: ...e it is possible to create one subsequent event Actions in the expert mode can use up to 8 time outputs The toolbar is displayed above the list of conditions and provides all the tools available for c...

Page 23: ...or returning to the conditions setting P Button for deleting a condition Q Button for condition configuration R Save button Creating a condition is divided into three parts z z Events z z Actions when...

Page 24: ...nth Time Setting a condition based on a particular time Day night Setting a condition based on whether it is day or night 29 Section events Sensors If more than one state is assigned to a sensor you c...

Page 25: ...the events that result when a condition is fulfilled The differences between the Basic and Expert mode are Basic mode the output state can only be specified as ON or OFF valid for both Fulfilled and N...

Page 26: ...he exact procedure to follow is dependent on the particular devices and operating systems you use and so should be performed by a person with the appropriate skills and knowledge If you want to view o...

Page 27: ...ather Station WARIO ME13 Manufacturer Headquarters and billing address WANET s r o voz 159 26 Hrad any 118 00 Prague 1 Czech Republic Service WANET s r o afa kov 1295 757 01 Vala sk Mezi Czech Republi...

Reviews: