Latitude (N)

Latitude of the station, value should be given as a decimal number (eg. 49.45820).

Longitude (E)

Longitude of the station, value should be given as a decimal number (eg. 18.14239).

15 

Section – Display

Tab – Meteo

This section allows specification of the display and position of the individual measured values 
at the Meteo tab. You can drag and drop the individual tabs or enable/disable them. The 
Meteo section is divided into two parts – the Main dashboard and the Extended dashboard. 
This is for viewing on devices with variable size of the display.

Default view configuration

This option is for configuring default view for the Meteo section.

Tab – View

Here you can specify the display and position of the individual measured values for the 
Overview tab.

Reset to default view

This option will restore the default view for the Overview tab.

16

Section – Email

This section is for specifying information regarding email communication. If you set 
a condition and select the option to send email when the condition is fulfilled, then it is 
necessary to make sure all these fields are correctly filled in in order for the email to be 
delivered. Servers that require SSL encryption for sending emails are not supported. After 
filling in the parameters for email communication it is good to test immediately, whether 
the setting is correct and the email sending function is working.

Sending emails

Enabling or disabling email sending feature.

Server

Name of the mail server.

Port

Port number of the mail server, default value is 25.

From

Email address of the sender.

Server authorization required

Enable this option if the mail server requires authorization for access.

User name

Specifying user name for access to your mailbox.

Summary of Contents for ME13

Page 1: ...User guide for IP Weather Station WARIO ME13 for firmware ME220005...

Page 2: ...s strana 11 Status LED diode strana 11 Reset and default button strana 11 Function Restart by pressing button strana 11 Function Default configuration by pressing button strana 11 5 Sensor range and r...

Page 3: ...heated rain gauge strana 16 Tab Device strana 16 Search devices strana 16 List of connected devices strana 16 14 Section Location strana 16 Location strana 16 Elevation strana 16 Geographical coordin...

Page 4: ...upport strana 20 Status LED diode setting strana 20 Information strana 20 21 Viewing measurements section Meteo strana 20 22 Description of the individual tabs in the Meteo section strana 21 23 Viewin...

Page 5: ...na 25 32 Section events Action condition met not met strana 25 Action Output setting strana 25 Set output to strana 25 Action Output timing strana 25 Select output strana 25 State strana 25 Maintain a...

Page 6: ...h are specified in a document available at www meteo pocasi cz and warranty is performed based on this document or the legislation of the Czech Republic Installation and configuration of the weather s...

Page 7: ...that are not used must be covered with rubber plugs which are also supplied with the station The weather station is equipped with locking connectors RJ11 and RJ45 for connecting the sensors and the da...

Page 8: ...9 9 9 Step 3 1 1 1 1 1 2 2 2 3 4 6 5 2 7 8 3 4 6 5 2 8 7 10 11 3 2 3 4 2 3 2 W 3 2 4 3 4 6 5 2 5 9 6 Connector for connecting rain gauge Signal LED diode Reset button Resets weather station to factory...

Page 9: ...nect the optional temperature or temperature humidity sensors to the receptacles labeled S1 or S2 z z Connect the relay outputs to receptacles OUT1 or OUT2 z z Connect the WBUS interface data cable to...

Page 10: ...r max 25 m LAN IPWeather Station WARIO ME13 WAN Internet 230V 12 Rain gauge 7 Wind speed and wind direction sensor POE adapter data cable Optional temperature and humidity sensors WBUS interface data...

Page 11: ...2 5 s then the green LED diode for 2 5 s and finally the red LED diode again for 2 5 s you can release the button and the z z solar radiation z z rain gauge optionally with automatic heating mechanis...

Page 12: ...aximum current of 0 25 A and voltage of 30 V Operating temperature of Weather station 30 to 65 C S1 and S2 connectors for independent cable temperature or temperature humidity sensors Range Resolution...

Page 13: ...e entire weather station Make sure all the parameters are properly set in order to ensure correct measurement and access to the actual station If you are accessing the Settings station for the very fi...

Page 14: ...ress configuration Proxy port Proxy server port configuration 10 Section Users This section is for specifying login details for access to the weather station If you forget the login information it wil...

Page 15: ...nality of the network device IP addresses of up to 8 sensors can be specified Label Option to name a particular sensor IP address Option to specify the IP address of a network device Tab measurement s...

Page 16: ...ThislistshowsalldevicescurrentlyconnectedtotheWBUS withthepossibilityofconfiguring or removing them 14 Section Location This section is to specify the location of the weather station in order to corre...

Page 17: ...for the Overview tab Reset to default view This option will restore the default view for the Overview tab 16 Section Email This section is for specifying information regarding email communication If y...

Page 18: ...here you want to send data Server can be specified either by its domain name or an IP address Port Configuration of the port number used for communication with the server in most cases set to 80 Addre...

Page 19: ...n about the station Serial Number Weather station serial number Model Weather station model Firmware Current firmware version installed in the station If the station is connected to the Internet a war...

Page 20: ...l information about the weather station 21 Viewing measurements section Meteo A B C G H I J K L 3 F D E A Weather station menu B Measured values sensors tab on the main dashboard C trend graph for the...

Page 21: ...w you previous value depending on the currently displayed value and time span H The Day button shows information for the current day and clicking the arrow next to it allows choosing any other day in...

Page 22: ...e it is possible to create one subsequent event Actions in the expert mode can use up to 8 time outputs The toolbar is displayed above the list of conditions and provides all the tools available for c...

Page 23: ...or returning to the conditions setting P Button for deleting a condition Q Button for condition configuration R Save button Creating a condition is divided into three parts z z Events z z Actions when...

Page 24: ...nth Time Setting a condition based on a particular time Day night Setting a condition based on whether it is day or night 29 Section events Sensors If more than one state is assigned to a sensor you c...

Page 25: ...the events that result when a condition is fulfilled The differences between the Basic and Expert mode are Basic mode the output state can only be specified as ON or OFF valid for both Fulfilled and N...

Page 26: ...he exact procedure to follow is dependent on the particular devices and operating systems you use and so should be performed by a person with the appropriate skills and knowledge If you want to view o...

Page 27: ...ather Station WARIO ME13 Manufacturer Headquarters and billing address WANET s r o voz 159 26 Hrad any 118 00 Prague 1 Czech Republic Service WANET s r o afa kov 1295 757 01 Vala sk Mezi Czech Republi...

Reviews: