Reverse osmosis system processing essentially consists in an adjustable reduction of fixed residue in treated water.
4. Conditions of use and period of use
11
This equipment is for the treatment of drinking water only. Input water must be drinkable according to the National and local
rules and standards in force in the Country of installation.
This equipment requires regular maintenance to guarantee the purity level of the output water within the limits declared by the
manufacturer.
Summary maintenance table
Description
Frequency
Action
Time of use
10 years
Service by Manufacturer or disposal.
See instructions for use.
Carbon filter cartridge life
Max. 6 months or exhaustion
Replacement and flush filter cartridge for 5 minutes.
See label on the equipment and instructions for use.
Resin filter cartridge life
Max. 6 months or exhaustion
Replacement.
See instructions for use.
Osmotic membrane life
Max. 4 years or exhaustion
Replacement.
See instructions for use.
Machine off without electrical supply
Over 10 days or time uncontrolled
Intervention to replace the:
•
Resin filter cartridge;
•
Osmotic membrane.
and:
•
disinfect the equipment (extraordinary intervention, contact
the dealer for the methods).
For the maintenance method, see the specific section (8).
Specific tests were carried out to define the time of use and the maintenance methods.
After installation, the equipment must be powered and flushed for at least 5/15 minutes, for hygiene reasons.
If the equipment is left unpowered for 10 days or more, replace the resin filter cartridge and sanitize the relevant vessel.