55
APPENDIX 1. Technical data
APPENDIX 1. Technical data
APPENDIX 1. Technical data
APPENDIX 1. Technical data
CONFORMITIES
CONFORMITIES
CONFORMITIES
CONFORMITIES
STERILIZER featuring
STERILIZER featuring
STERILIZER featuring
STERILIZER featuring type
type
type
type B sterilization
B sterilization
B sterilization
B sterilization cycles conform with the
cycles conform with the
cycles conform with the
cycles conform with the following
following
following
following standards:
standards:
standards:
standards:
93/42/CEE
Medical Device Directive (MDD)
97/23/CEE
Pressure Equipment Directive (PED)
2002/96/CEE
Waste Electrical and Electronic Equipment (WEEE)
EN 13060
Small steam sterilizer
IEC 61010-1
Safety requirements for electrical equipment for measurement, control and
laboratory use, general requirements
IEC 61010-2-040
Safety requirements for electrical equipment for measurement, control and
laboratory use; particular requirements for autoclaves using steam for the
treatment of medical materials and for laboratory processes.
EN 61326
Electrical equipment for measurement, control and laboratory use: EMC
requirements.
PRODUCT LABELS
PRODUCT LABELS
PRODUCT LABELS
PRODUCT LABELS
Data plate
Sterilization chamber label
Manufacturer label
TECHNICAL DATA
TECHNICAL DATA
TECHNICAL DATA
TECHNICAL DATA
Electrical
Electrical
Electrical
Electrical supply
supply
supply
supply::::
Nominal voltage:
Max. power:
Max. current:
200 - 240 VAC – 50/60 Hz, single - phase
200 - 240 VAC
1750 W
8.75 A
Sterilizer
Sterilizer
Sterilizer
Sterilizer:
Working temperature:
Working relative humidity:
Storage temperature /rel. humidity:
Max altitude:
Min. atmospheric pressure:
Overall dimensions:
Min. space required:
Size of the door movement:
Weight empty:
Max. weight (fully loaded):
Max. weight per support area:
Max. heat output:
Max noise level:
from +5
°
C to +40
°
C
Max. RH 80% up to 31
°
C, linearly decreasing to 50% at 40
°
C
-20
°
C to +60
°
C/0-90% (with empty tanks)
4000m asl
0.6 barA
W: 450 mm/H: 435 mm/D: 599 mm
W: 470 mm/H: 485 mm/D: 650 mm
W: 360 mm/H: 410 mm/D: 360 mm
38 kg (LINA MB17), 40.5 kg (LINA MB22)
50 kg (LINA MB17), 53 kg (LINA MB22)
785 kN/mm2
3000 KJoule/hour
63 dB
Pressure safety valve:
Safety thermostat
3 bar
330
°
C
Sterilizer
Sterilizer
Sterilizer
Sterilizer chamber
chamber
chamber
chamber::::
Total volume:
Usable space (for all cycles)
Bacteriological filter:
17 l/Ø 250 mm x D 362 mm (LINA MB17)
22 l/Ø 250 mm x D 440 mm (LINA MB22)
12 l/W195 mm x H 195 mm x D 297 mm (LINA MB17))
15.5 l/W 195 mm x H 195 mm x D 390 mm (LINA MB22)
0.3 µm
Distilled
Distilled
Distilled
Distilled or
or
or
or demineralized
demineralized
demineralized
demineralized water
water
water
water::::
Water quality:
Average water consumption:
Tank volume:
Fulfilling EN 13060 Ann. C (conductivity < 15μS/cm)
0.7 litres/cycle
2 x 3.6 liters
External
External
External
External water
water
water
water supply
supply
supply
supply::::
Pressure:
Flow:
To be compliant with IEC61770
min. 2 bar – max. 8.6 bar
min. 0.25 – max 0.5 l/min
Communication
Communication
Communication
Communication with
with
with
with other
other
other
other devices
devices
devices
devices::::
1 serial port (optional: USB + 2 serial ports)
Other
Other
Other
Other
Fully micro-processor controlled, process evaluation system
according to EN13060.
Programmable sleep-mode.
Summary of Contents for LINA MB17
Page 73: ...Notes Notes Notes Notes...
Page 74: ......