Revision 1
19
Product Manual PSH-30 series Hand Wash Dryer
Figure 13: Air duct to fascia
Figure 14: Earth wire to fascia
Figure 15: Soap tube to fascia
1) Check the installation position of the control module relative to the bowl, then cut
the air hose to length, a hacksaw or snips may be required to cut through the
core of the hose. The hose can then be attached to the fascia air duct adaptor
using one of the jubilee clips provided.
2) Connect the M6 end of the earth wire to the rear of the fascia, Ensure there is a
spring washer on either side of the ring terminal.
3) The soap tube is to be pushed onto the barbed fitting on the rear of the fascia
and cable tied in place.